80 Hz but not 40 Hz, transcranial alternating current stimulation of 80 Hz over right intraparietal sulcus increases visuospatial working memory capacity
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Park, Jimin | - |
dc.contributor.author | Lee, Chany | - |
dc.contributor.author | Lee, Sangjun | - |
dc.contributor.author | Im, Chang-Hwan | - |
dc.date.accessioned | 2023-08-16T09:30:11Z | - |
dc.date.available | 2023-08-16T09:30:11Z | - |
dc.date.created | 2022-09-02 | - |
dc.date.issued | 2022-08 | - |
dc.identifier.issn | 2045-2322 | - |
dc.identifier.uri | http://scholarworks.bwise.kr/kbri/handle/2023.sw.kbri/210 | - |
dc.description.abstract | Working memory (WM) is a complex cognitive function involved in the temporary storage and manipulation of information, which has been one of the target cognitive functions to be restored in neurorehabilitation. WM capacity is known to be proportional to the number of gamma cycles nested in a single theta cycle. Therefore, gamma-band transcranial alternating current stimulation (tACS) should be dependent of the stimulation frequency; however, the results of previous studies that employed 40 Hz tACS have not been consistent. The optimal locations and injection currents of multiple scalp electrodes were determined based on numerical simulations of electric field. Experiments were conducted with 20 healthy participants. The order of three stimulation conditions (40 Hz tACS, 80 Hz tACS, and sham stimulation) were randomized but counterbalanced. Visual hemifield-specific visual WM capacity was assessed using a delayed visual match to the sample task. High gamma tACS significantly increased WM capacity, while low gamma tACS had no significant effect. Notably, 80 Hz tACS increased WM capacity on both the left and right visual hemifields, while previous tACS studies only reported the effects of tACS on contralateral hemifields. This is the first study to investigate the frequency-dependent effect of gamma-band tACS on WM capacity. Our findings also suggest that high gamma tACS might influence not only WM capacity but also communication between interhemispheric cortical regions. It is expected that high gamma tACS could be a promising neurorehabilitation method to enhance higher-order cognitive functions with similar mechanisms. | - |
dc.language | 영어 | - |
dc.language.iso | en | - |
dc.publisher | Nature Publishing Group | - |
dc.title | 80 Hz but not 40 Hz, transcranial alternating current stimulation of 80 Hz over right intraparietal sulcus increases visuospatial working memory capacity | - |
dc.type | Article | - |
dc.contributor.affiliatedAuthor | Lee, Chany | - |
dc.identifier.doi | 10.1038/s41598-022-17965-8 | - |
dc.identifier.wosid | 000840132800059 | - |
dc.identifier.bibliographicCitation | Scientific Reports, v.12, no.1 | - |
dc.relation.isPartOf | Scientific Reports | - |
dc.citation.title | Scientific Reports | - |
dc.citation.volume | 12 | - |
dc.citation.number | 1 | - |
dc.type.rims | ART | - |
dc.type.docType | Article | - |
dc.description.journalClass | 1 | - |
dc.description.isOpenAccess | Y | - |
dc.description.journalRegisteredClass | scie | - |
dc.description.journalRegisteredClass | scopus | - |
dc.relation.journalResearchArea | Science & Technology - Other Topics | - |
dc.relation.journalWebOfScienceCategory | Multidisciplinary Sciences | - |
dc.subject.keywordPlus | GAMMA-BAND ACTIVITY | - |
dc.subject.keywordPlus | SHORT-TERM-MEMORY | - |
dc.subject.keywordPlus | OSCILLATIONS | - |
dc.subject.keywordPlus | ATTENTION | - |
dc.subject.keywordPlus | CORTEX | - |
dc.subject.keywordPlus | VARIABILITY | - |
dc.subject.keywordPlus | PHASE | - |
dc.subject.keywordPlus | TASK | - |
dc.subject.keywordPlus | BETA | - |
dc.subject.keywordPlus | TACS | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
61, Cheomdan-ro, Dong-gu, Daegu, Republic of Korea , 41062 053-980-8114
COPYRIGHT Korea Brain Research Institute. ALL RIGHTS RESERVED.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.