Design of Rotated Surface Coil Array for Multiple-Subject Imaging at 400 MHz
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Nam, Taewoo | - |
dc.contributor.author | Kim, Donghyuk | - |
dc.contributor.author | Seo, Minyeong | - |
dc.contributor.author | Im, Geunho | - |
dc.contributor.author | Hernandez, Daniel | - |
dc.contributor.author | Lee, Taekwan | - |
dc.contributor.author | Kim, Kyoung-Nam | - |
dc.date.accessioned | 2023-08-16T09:30:13Z | - |
dc.date.available | 2023-08-16T09:30:13Z | - |
dc.date.created | 2022-07-15 | - |
dc.date.issued | 2022-07 | - |
dc.identifier.issn | 2169-3536 | - |
dc.identifier.uri | http://scholarworks.bwise.kr/kbri/handle/2023.sw.kbri/221 | - |
dc.description.abstract | Multiple-subject magnetic resonance imaging has been used in phenotyping studies to reduce the total experimental time by simultaneously capturing images of multiple animals using single or multiple radio frequency (RF) coils. However, conventional methods must consider decoupling circuits to minimize the mutual inductance coupling between RF coils. These decoupling circuits unnecessarily increase the field of view and image acquisition times. In this study, we propose a rotated surface (RS) coil that can generate a uniformly transmitted magnetic field (vertical bar B-1(+)vertical bar) and minimize the distance between coils when used for multiple-animal imaging without decoupling circuits. The RS coil was designed using an electromagnetic (EM) simulation software, and the rotation angle, which creates a uniform vertical bar B-1(+)vertical bar-component, was derived by mathematical calculations. We compared the vertical bar B-1(+)vertical bar-component uniformity produced by RS coils with different rotation angles and a 4-leg high-pass filter birdcage coil in multiple-coil arrays at the same location using EM simulations. The RS coil displayed a uniformity greater than 94% and 84% uniformity when used as a single-channel and multiple-coil array in the central axial plane, respectively. Following the EM simulations, a multiple-mice RS coil array was manufactured, and a bench test was performed to ensure its operation at 400 MHz and for coupling analysis. T1-FLASH images of the four phantoms and mice were acquired using a multiple RS coil array in a 9.4-T preclinical MR system. The signal-to-noise ratio and uniformity were measured using the phantom images. | - |
dc.language | 영어 | - |
dc.language.iso | en | - |
dc.publisher | Institute of Electrical and Electronics Engineers Inc. | - |
dc.title | Design of Rotated Surface Coil Array for Multiple-Subject Imaging at 400 MHz | - |
dc.type | Article | - |
dc.contributor.affiliatedAuthor | Lee, Taekwan | - |
dc.identifier.doi | 10.1109/ACCESS.2022.3183119 | - |
dc.identifier.wosid | 000818793300001 | - |
dc.identifier.bibliographicCitation | IEEE Access, v.10, pp.66281 - 66289 | - |
dc.relation.isPartOf | IEEE Access | - |
dc.citation.title | IEEE Access | - |
dc.citation.volume | 10 | - |
dc.citation.startPage | 66281 | - |
dc.citation.endPage | 66289 | - |
dc.type.rims | ART | - |
dc.type.docType | Article | - |
dc.description.journalClass | 1 | - |
dc.description.isOpenAccess | Y | - |
dc.description.journalRegisteredClass | scie | - |
dc.description.journalRegisteredClass | scopus | - |
dc.relation.journalResearchArea | Computer Science | - |
dc.relation.journalResearchArea | Engineering | - |
dc.relation.journalResearchArea | Telecommunications | - |
dc.relation.journalWebOfScienceCategory | Computer Science, Information Systems | - |
dc.relation.journalWebOfScienceCategory | Engineering, Electrical & Electronic | - |
dc.relation.journalWebOfScienceCategory | Telecommunications | - |
dc.subject.keywordPlus | MOUSE | - |
dc.subject.keywordPlus | MRI | - |
dc.subject.keywordAuthor | Rotated surface coil | - |
dc.subject.keywordAuthor | rotation angle | - |
dc.subject.keywordAuthor | magnetic resonance imaging | - |
dc.subject.keywordAuthor | multiple-subject | - |
dc.subject.keywordAuthor | phenotyping | - |
dc.subject.keywordAuthor | radio frequency coil | - |
dc.subject.keywordAuthor | uniformity | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
61, Cheomdan-ro, Dong-gu, Daegu, Republic of Korea , 41062 053-980-8114
COPYRIGHT Korea Brain Research Institute. ALL RIGHTS RESERVED.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.