Detailed Information

Cited 3 time in webofscience Cited 4 time in scopus
Metadata Downloads

In-vivo estimation of tissue electrical conductivities of a rabbit eye for precise simulation of electric field distributions during ocular iontophoresis

Authors
Lee, SangjunLee, ChanyKim, EuijinKo, Song AhKim, Se-NaChoy, Young BinIm, Chang-Hwan
Issue Date
Jan-2022
Publisher
John Wiley & Sons Ltd.
Keywords
electrical conductivity; finite element method; ocular iontophoresis; optimization; rabbit eye
Citation
International Journal for Numerical Methods in Biomedical Engineering, v.38, no.1
Journal Title
International Journal for Numerical Methods in Biomedical Engineering
Volume
38
Number
1
URI
http://scholarworks.bwise.kr/kbri/handle/2023.sw.kbri/260
DOI
10.1002/cnm.3540
ISSN
2040-7939
Abstract
Precise estimation of electrical conductivity of the eyes is important for the accurate analysis of electric field distributions in the eyes during ocular iontophoresis. In this study, we estimated the tissue electrical conductivities of a rabbit eye, which has been widely employed for neuro-ophthalmological experiments, through an in vivo experiment for the first time. Electrical potentials were measured at multiple locations on the skin, while weak currents were transmitted into the skin via two surface electrodes attached to the skin around the eye. A finite element model was constructed to calculate the electric potentials at the measurement locations. The conductivity values of different tissues were then estimated using an optimization procedure to minimize the difference between the measured and calculated electric potentials. The accuracy of the estimated tissue conductivity values of the rabbit eye was validated by comparing the measured and calculated electric potential values for different electrode montages. Further multi-physical analyses of iontophoretic drug delivery to the rabbit eye showed a significant influence of the conductivity profile on the resultant particle distribution. Overall, our results provide an important reference for the tissue electrical conductivity values of the rabbit eye, which could be further utilized for designing new medical devices for delivering electric fields to the eyes, such as transorbital and transscleral electrical stimulations.
Files in This Item
There are no files associated with this item.
Appears in
Collections
연구본부 > 인지과학 연구그룹 > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Lee, Chany photo

Lee, Chany
연구본부 (인지과학 연구그룹)
Read more

Altmetrics

Total Views & Downloads

BROWSE