Detailed Information

Cited 33 time in webofscience Cited 37 time in scopus
Metadata Downloads

Transcranial focused ultrasound stimulation with high spatial resolution

Authors
Kim, SeongyeonJo, YehhyunKook, GeonPasquinelli, CristinaKim, HyunggugKim, KipomHoe, Hyang-SookChoe, YoungshikRhim, HyewhonThielscher, AxelKim, JeongyeonLee, Hyunjoo Jenny
Issue Date
Mar-2021
Publisher
ELSEVIER SCIENCE INC
Keywords
Ultrasound neuromodulation; Brain stimulation; High spatial resolution
Citation
BRAIN STIMULATION, v.14, no.2, pp.290 - 300
Journal Title
BRAIN STIMULATION
Volume
14
Number
2
Start Page
290
End Page
300
URI
http://scholarworks.bwise.kr/kbri/handle/2023.sw.kbri/539
DOI
10.1016/j.brs.2021.01.002
ISSN
1935-861X
Abstract
Background: Low-intensity transcranial focused ultrasound stimulation is a promising candidate for noninvasive brain stimulation and accurate targeting of brain circuits because of its focusing capability and long penetration depth. However, achieving a sufficiently high spatial resolution to target small animal sub-regions is still challenging, especially in the axial direction. Objective: To achieve high axial resolution, we designed a dual-crossed transducer system that achieved high spatial resolution in the axial direction without complex microfabrication, beamforming circuitry, and signal processing. Methods: High axial resolution was achieved by crossing two ultrasound beams of commercially available piezoelectric curved transducers at the focal length of each transducer. After implementation of the fixture for the dual-crossed transducer system, three sets of in vivo animal experiments were conducted to demonstrate high target specificity of ultrasound neuromodulation using the dual-crossed transducer system (n = 38). Results: The full-width at half maximum (FWHM) focal volume of our dual-crossed transducer system was under 0.52 mm(3). We report a focal diameter in both lateral and axial directions of 1 mm. To demonstrate successful in vivo brain stimulation of wild-type mice, we observed the movement of the forepaws. In addition, we targeted the habenula and verified the high spatial specificity of our dual crossed transducer system. Conclusions: Our results demonstrate the ability of the dual-crossed transducer system to target highly specific regions of mice brains using ultrasound stimulation. The proposed system is a valuable tool to study the complex neurological circuitry of the brain noninvasively. (C) 2021 The Author(s). Published by Elsevier Inc.
Files in This Item
There are no files associated with this item.
Appears in
Collections
연구본부 > 퇴행성 뇌질환 연구그룹 > 1. Journal Articles
연구본부 > 뇌발달질환 연구그룹 > 1. Journal Articles
연구본부 > 정서·인지 질환 연구그룹 > 1. Journal Articles
연구전략실 > 인프라구축팀 > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Hoe, Hyang Sook photo

Hoe, Hyang Sook
연구본부 (퇴행성뇌질환 연구그룹)
Read more

Altmetrics

Total Views & Downloads

BROWSE