Deep Learning-Based Computed Tomography Image Standardization to Improve Generalizability of Deep Learning-Based Hepatic Segmentation
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Lee Seul Bi | - |
dc.contributor.author | Hong Youngtaek | - |
dc.contributor.author | Cho Yeon Jin | - |
dc.contributor.author | Jeong Dawun | - |
dc.contributor.author | Lee Jina | - |
dc.contributor.author | Yoon Soon Ho | - |
dc.contributor.author | Lee Seunghyun | - |
dc.contributor.author | Choi Young Hun | - |
dc.contributor.author | Cheon Jung-Eun | - |
dc.date.accessioned | 2023-08-16T09:48:21Z | - |
dc.date.available | 2023-08-16T09:48:21Z | - |
dc.date.created | 2023-06-30 | - |
dc.date.issued | 2023-04 | - |
dc.identifier.issn | 1229-6929 | - |
dc.identifier.uri | http://scholarworks.bwise.kr/kbri/handle/2023.sw.kbri/613 | - |
dc.description.abstract | Objective: We aimed to investigate whether image standardization using deep learning-based computed tomography (CT) image conversion would improve the performance of deep learning-based automated hepatic segmentation across various reconstruction methods. Materials and Methods: We collected contrast-enhanced dual-energy CT of the abdomen that was obtained using various reconstruction methods, including filtered back projection, iterative reconstruction, optimum contrast, and monoenergetic images with 40, 60, and 80 keV. A deep learning based image conversion algorithm was developed to standardize the CT images using 142 CT examinations (128 for training and 14 for tuning). A separate set of 43 CT examinations from 42 patients (mean age, 10.1 years) was used as the test data. A commercial software program (MEDIP PRO v2.0.0.0, MEDICALIP Co. Ltd.) based on 2D U-NET was used to create liver segmentation masks with liver volume. The original 80 keV images were used as the ground truth. We used the paired t-test to compare the segmentation performance in the Dice similarity coefficient (DSC) and difference ratio of the liver volume relative to the ground truth volume before and after image standardization. The concordance correlation coefficient (CCC) was used to assess the agreement between the segmented liver volume and ground-truth volume. Results: The original CT images showed variable and poor segmentation performances. The standardized images achieved significantly higher DSCs for liver segmentation than the original images (DSC [original, 5.40%–91.27%] vs. [standardized, 93.16%–96.74%], all P < 0.001). The difference ratio of liver volume also decreased significantly after image conversion (original, 9.84%–91.37% vs. standardized, 1.99%–4.41%). In all protocols, CCCs improved after image conversion (original, -0.006–0.964 vs. standardized, 0.990–0.998). Conclusion: Deep learning-based CT image standardization can improve the performance of automated hepatic segmentation using CT images reconstructed using various methods. Deep learning-based CT image conversion may have the potential to improve the generalizability of the segmentation network. | - |
dc.language | 영어 | - |
dc.language.iso | en | - |
dc.publisher | 대한영상의학회 | - |
dc.title | Deep Learning-Based Computed Tomography Image Standardization to Improve Generalizability of Deep Learning-Based Hepatic Segmentation | - |
dc.title.alternative | Deep Learning-Based Computed Tomography Image Standardization to Improve Generalizability of Deep Learning-Based Hepatic Segmentation | - |
dc.type | Article | - |
dc.contributor.affiliatedAuthor | Lee Seunghyun | - |
dc.identifier.doi | 10.3348/kjr.2022.0588 | - |
dc.identifier.scopusid | 2-s2.0-85151573413 | - |
dc.identifier.bibliographicCitation | Korean Journal of Radiology, v.24, no.4, pp.294 - 304 | - |
dc.relation.isPartOf | Korean Journal of Radiology | - |
dc.citation.title | Korean Journal of Radiology | - |
dc.citation.volume | 24 | - |
dc.citation.number | 4 | - |
dc.citation.startPage | 294 | - |
dc.citation.endPage | 304 | - |
dc.type.rims | ART | - |
dc.identifier.kciid | ART002941229 | - |
dc.description.journalClass | 1 | - |
dc.description.journalRegisteredClass | scie | - |
dc.description.journalRegisteredClass | scopus | - |
dc.description.journalRegisteredClass | kci | - |
dc.subject.keywordAuthor | Artificial intelligence | - |
dc.subject.keywordAuthor | Automated segmentation | - |
dc.subject.keywordAuthor | Image conversion | - |
dc.subject.keywordAuthor | Quality control | - |
dc.subject.keywordAuthor | Reproducibility | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
61, Cheomdan-ro, Dong-gu, Daegu, Republic of Korea , 41062 053-980-8114
COPYRIGHT Korea Brain Research Institute. ALL RIGHTS RESERVED.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.