Safety and efficacy of a metal stent covered with a silicone membrane containing integrated silver particles in preventing biofilm and sludge formation in endoscopic drainage of malignant biliary obstruction: a phase 2 pilot study
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Lee, Tae Hoon | - |
dc.contributor.author | Jung, Min Kyo | - |
dc.contributor.author | Kim, Tae-Keun | - |
dc.contributor.author | Pack, Chan Gi | - |
dc.contributor.author | Park, Yoon Kyung | - |
dc.contributor.author | Kim, Seon-Ok | - |
dc.contributor.author | Park, Do Hyun | - |
dc.date.accessioned | 2023-08-16T09:48:30Z | - |
dc.date.available | 2023-08-16T09:48:30Z | - |
dc.date.created | 2022-01-13 | - |
dc.date.issued | 2019-10 | - |
dc.identifier.issn | 0016-5107 | - |
dc.identifier.uri | http://scholarworks.bwise.kr/kbri/handle/2023.sw.kbri/666 | - |
dc.description.abstract | Background and Aims: Membrane-covered self-expandable metal stents (SEMSs) have been developed to prolong the patency of stents by reducing tissue hyperplasia or tumor ingrowth. However, their effectiveness is attenuated by stent clogging as a result of biofilm formation on the inner surface of the membrane. The aim of this pilot study was to evaluate the efficacy and safety of SEMSs covered with a silicone membrane containing integrated silver particles (Ag-P) in malignant distal biliary obstruction. Methods: Twenty-four patients who underwent SEMS placement because of malignant distal biliary obstruction were enrolled in this single-center pilot study. The main outcomes were technical success, clinical success, adverse events, stent patency, and survival. Results: The technical and clinical success rates were 100% and 91.7% (22 of 24), respectively. The rates of early and late adverse events were 22.7% and 36.4%, respectively. The primary reintervention rate was 27.3% (6 of 22). Only 1 case involving stent malfunction was associated with sludge impaction. Median stent patency was 179 days. During follow-up, there were no serious adverse events or mortality related to the stents or Ag-P. Serum and urine silver concentrations before and after stent placement and at 32 weeks after placement did not differ. All serum and urine silver concentrations were <3 mu g/L (3 ppb) and 5 mu g/L (5 ppb), respectively. Conclusions: SEMSs covered with a silicone membrane containing integrated Ag-Ps may be effective and safe in malignant distal biliary obstruction. Stent dysfunction related to sludge impaction may be less frequent using this new stent. | - |
dc.language | 영어 | - |
dc.language.iso | en | - |
dc.publisher | MOSBY-ELSEVIER | - |
dc.title | Safety and efficacy of a metal stent covered with a silicone membrane containing integrated silver particles in preventing biofilm and sludge formation in endoscopic drainage of malignant biliary obstruction: a phase 2 pilot study | - |
dc.type | Article | - |
dc.contributor.affiliatedAuthor | Jung, Min Kyo | - |
dc.identifier.doi | 10.1016/j.gie.2019.06.007 | - |
dc.identifier.scopusid | 2-s2.0-85069916135 | - |
dc.identifier.wosid | 000486385600018 | - |
dc.identifier.bibliographicCitation | GASTROINTESTINAL ENDOSCOPY, v.90, no.4, pp.663 - + | - |
dc.relation.isPartOf | GASTROINTESTINAL ENDOSCOPY | - |
dc.citation.title | GASTROINTESTINAL ENDOSCOPY | - |
dc.citation.volume | 90 | - |
dc.citation.number | 4 | - |
dc.citation.startPage | 663 | - |
dc.citation.endPage | + | - |
dc.type.rims | ART | - |
dc.type.docType | Article | - |
dc.description.journalClass | 1 | - |
dc.description.isOpenAccess | N | - |
dc.description.journalRegisteredClass | scie | - |
dc.description.journalRegisteredClass | scopus | - |
dc.relation.journalResearchArea | Gastroenterology & Hepatology | - |
dc.relation.journalWebOfScienceCategory | Gastroenterology & Hepatology | - |
dc.subject.keywordPlus | IN-VITRO EVALUATION | - |
dc.subject.keywordPlus | BACTERIAL BIOFILM | - |
dc.subject.keywordPlus | NANOPARTICLES | - |
dc.subject.keywordPlus | MULTICENTER | - |
dc.subject.keywordPlus | PALLIATION | - |
dc.subject.keywordPlus | STRICTURES | - |
dc.subject.keywordPlus | MIGRATION | - |
dc.subject.keywordPlus | BLOCKAGE | - |
dc.subject.keywordPlus | PATENCY | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
61, Cheomdan-ro, Dong-gu, Daegu, Republic of Korea , 41062 053-980-8114
COPYRIGHT Korea Brain Research Institute. ALL RIGHTS RESERVED.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.