Geometric decoupling using clip-path conductors for whole-brain transceiver array at 7 T
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Nam, Taewoo | - |
dc.contributor.author | Kim, Donghyuk | - |
dc.contributor.author | Hernandez, Daniel | - |
dc.contributor.author | Lee, Taekwan | - |
dc.contributor.author | Noh, Young | - |
dc.contributor.author | Kim, Kyoung-Nam | - |
dc.date.accessioned | 2023-09-26T06:00:00Z | - |
dc.date.available | 2023-09-26T06:00:00Z | - |
dc.date.created | 2023-09-26 | - |
dc.date.issued | 2023-10 | - |
dc.identifier.issn | 0263-2241 | - |
dc.identifier.uri | http://scholarworks.bwise.kr/kbri/handle/2023.sw.kbri/989 | - |
dc.description.abstract | In magnetic resonance imaging (MRI), a radiofrequency (RF) coil array with a large number of elements is commonly employed for transmission and reception to improve the uniformity of the RF transmitting magnetic field and increase the signal-to-noise ratio. Additionally, multi-element RF arrays can reduce the acquisition time using the parallel imaging technique. However, mutual inductance coupling is unavoidable in multi-element RF coil arrays. Therefore, many researchers have studied geometric and artificial decoupling techniques to minimize mutual inductance coupling. This study proposes a decoupling method using clip-path conductors (CPCs). The CPC geometry locates the top-right and bottom-left positions in the loop coil to reduce the mutual inductance coupling between adjacent elements. The decoupling performance of the CPC coil was verified via electromagnetic simulations and bench measurements. An eight-element transceiver CPC array was manufactured, and phantom and healthy volunteer images were acquired using a 7-T MRI system. | - |
dc.language | 영어 | - |
dc.language.iso | en | - |
dc.publisher | ELSEVIER SCI LTD | - |
dc.title | Geometric decoupling using clip-path conductors for whole-brain transceiver array at 7 T | - |
dc.type | Article | - |
dc.contributor.affiliatedAuthor | Lee, Taekwan | - |
dc.identifier.doi | 10.1016/j.measurement.2023.113373 | - |
dc.identifier.scopusid | 2-s2.0-85166481591 | - |
dc.identifier.wosid | 001052919100001 | - |
dc.identifier.bibliographicCitation | MEASUREMENT, v.220 | - |
dc.relation.isPartOf | MEASUREMENT | - |
dc.citation.title | MEASUREMENT | - |
dc.citation.volume | 220 | - |
dc.type.rims | ART | - |
dc.type.docType | Article | - |
dc.description.journalClass | 1 | - |
dc.description.isOpenAccess | Y | - |
dc.description.journalRegisteredClass | scie | - |
dc.description.journalRegisteredClass | scopus | - |
dc.relation.journalResearchArea | Engineering | - |
dc.relation.journalResearchArea | Instruments & Instrumentation | - |
dc.relation.journalWebOfScienceCategory | Engineering, Multidisciplinary | - |
dc.relation.journalWebOfScienceCategory | Instruments & Instrumentation | - |
dc.subject.keywordPlus | COIL ARRAY | - |
dc.subject.keywordPlus | PARALLEL | - |
dc.subject.keywordPlus | EXCITATION | - |
dc.subject.keywordPlus | COMPONENTS | - |
dc.subject.keywordPlus | DESIGN | - |
dc.subject.keywordPlus | POWER | - |
dc.subject.keywordPlus | HEAD | - |
dc.subject.keywordPlus | SAR | - |
dc.subject.keywordAuthor | Clip-path conductor | - |
dc.subject.keywordAuthor | Magnetic resonance imaging | - |
dc.subject.keywordAuthor | RF coil | - |
dc.subject.keywordAuthor | Multi-element | - |
dc.subject.keywordAuthor | Mutual inductance coupling | - |
dc.subject.keywordAuthor | Decoupling | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
61, Cheomdan-ro, Dong-gu, Daegu, Republic of Korea , 41062 053-980-8114
COPYRIGHT Korea Brain Research Institute. ALL RIGHTS RESERVED.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.