Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

자궁경부암 세포를 위한 광학 모니터링 시스템의 설계 및 분석

Full metadata record
DC Field Value Language
dc.contributor.authorSe-woon Choe-
dc.date.accessioned2021-11-05T02:46:11Z-
dc.date.available2021-11-05T02:46:11Z-
dc.date.created2021-02-23-
dc.date.issued2020-11-
dc.identifier.issn1975-8359-
dc.identifier.urihttps://scholarworks.bwise.kr/kumoh/handle/2020.sw.kumoh/20056-
dc.description.abstractFlow cytometer is a device for precise analysis of cells by measuring scattering of light and fluorescence according to the cell type. It is used for various purposes in many fields such as molecular biology, immunology, and pathology. However, flow cytometry is expensive and inconvenient in terms of maintenance when simple comparisons between cells are performed or when only simple measurement such as the number of cells is required. In this study, we designed a system that can measure forward scatter, side scatter, and fluorescent scatter using LED and photodiode. As a result, it was possible to measure the fluorescence scattering of cervical cancer cells stained with Calcein AM or DiD, and a high linear relationship with the number of cells was confirmed.-
dc.publisherThe Korean Institute of Electrical Engineers-
dc.title자궁경부암 세포를 위한 광학 모니터링 시스템의 설계 및 분석-
dc.title.alternativeDesign and analysis of an optical monitoring system for cervical cancer cells-
dc.typeArticle-
dc.contributor.affiliatedAuthorSe-woon Choe-
dc.identifier.bibliographicCitationThe Transactions of the Korean Institute of Electrical Engineers, v.69, no.11, pp.1761 - 1766-
dc.relation.isPartOfThe Transactions of the Korean Institute of Electrical Engineers-
dc.citation.titleThe Transactions of the Korean Institute of Electrical Engineers-
dc.citation.volume69-
dc.citation.number11-
dc.citation.startPage1761-
dc.citation.endPage1766-
dc.type.rimsART-
dc.identifier.kciidART002643574-
dc.description.journalClass1-
dc.description.isOpenAccessN-
dc.description.journalRegisteredClassscopus-
dc.description.journalRegisteredClasskci-
dc.subject.keywordAuthorCancer Cells-
dc.subject.keywordAuthorflow cytometry-
dc.subject.keywordAuthorfluorescence-
dc.subject.keywordAuthorLED-
dc.subject.keywordAuthorOptical Characteristics-
dc.subject.keywordAuthorPhotodiode-
dc.subject.keywordAuthorScattering of light-
Files in This Item
There are no files associated with this item.
Appears in
Collections
Department of Medical IT Convergence Engineering > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Choe, Se-woon photo

Choe, Se-woon
College of Engineering (Department of Medical IT Convergence Engineering)
Read more

Altmetrics

Total Views & Downloads

BROWSE