Detailed Information

Cited 14 time in webofscience Cited 16 time in scopus
Metadata Downloads

The effects of liquid height/volume, initial concentration of reactant and acoustic power on sonochemical oxidation

Full metadata record
DC Field Value Language
dc.contributor.authorLim, Myunghee-
dc.contributor.authorAshokkumar, Muthupandian-
dc.contributor.authorSon, Younggyu-
dc.date.available2020-04-24T12:25:26Z-
dc.date.created2020-03-31-
dc.date.issued2014-11-
dc.identifier.issn1350-4177-
dc.identifier.urihttps://scholarworks.bwise.kr/kumoh/handle/2020.sw.kumoh/2018-
dc.description.abstractEven though much knowledge on acoustic cavitation and its application has been accumulated over the past decades, further research is still required to develop industrial uses of acoustic cavitation. It is because the available information is mainly based on small-scale sonoreactors and the design and optimization of sonoreactors for large-scale applications have not been widely studied. In this study, the effects of liquid height/volume, initial concentration of the reactant and input acoustic power on sonochemical oxidation reactions including iodide ion oxidation, As(III) oxidation, and hydrogen peroxide generation were investigated using a 291 kHz sonoreactor with various liquid height/volumes (50, 100, 200, 300, 500, and 1000 mL) and input powers (23, 40, and 82 W). As the liquid height/volume and the input power changed, the power density varied from 23 to 1640 W/L and the maximum cavitation yields of triiodide ion for 23, 40, and 82 W were observed at 0.05, 0.1, and 0.2/0.3 L, respectively. It was found that low power was more effective for the small volume and the large volume required high power level and the moderate power density, approximately 400 W/L, was suggested for the sonochemical oxidation of iodide ion in the 291 kHz sonoreactor in this study. Similar results were observed in the generation of hydrogen peroxide and the sonochemical oxidation of As(III) to As(V). It was also revealed that KI dosimetry could be applicable for the estimation of the sonochemical reactions of non-volatile compounds such as As(III). (C) 2014 Elsevier B.V. All rights reserved.-
dc.language영어-
dc.language.isoen-
dc.publisherELSEVIER SCIENCE BV-
dc.subjectULTRASONIC FREQUENCY-
dc.subjectAQUEOUS-SOLUTION-
dc.subjectDEGRADATION-
dc.subjectCAVITATION-
dc.subjectSONOLYSIS-
dc.subjectLYSOZYME-
dc.subjectREACTORS-
dc.subjectENERGY-
dc.subjectGREEN-
dc.titleThe effects of liquid height/volume, initial concentration of reactant and acoustic power on sonochemical oxidation-
dc.typeArticle-
dc.contributor.affiliatedAuthorSon, Younggyu-
dc.identifier.doi10.1016/j.ultsonch.2014.03.005-
dc.identifier.scopusid2-s2.0-84904044268-
dc.identifier.wosid000340020500015-
dc.identifier.bibliographicCitationULTRASONICS SONOCHEMISTRY, v.21, no.6, pp.1988 - 1993-
dc.citation.titleULTRASONICS SONOCHEMISTRY-
dc.citation.volume21-
dc.citation.number6-
dc.citation.startPage1988-
dc.citation.endPage1993-
dc.type.rimsART-
dc.type.docTypeArticle-
dc.description.journalClass1-
dc.subject.keywordPlusULTRASONIC FREQUENCY-
dc.subject.keywordPlusAQUEOUS-SOLUTION-
dc.subject.keywordPlusDEGRADATION-
dc.subject.keywordPlusCAVITATION-
dc.subject.keywordPlusSONOLYSIS-
dc.subject.keywordPlusLYSOZYME-
dc.subject.keywordPlusREACTORS-
dc.subject.keywordPlusENERGY-
dc.subject.keywordPlusGREEN-
dc.subject.keywordAuthorSonoreactor design-
dc.subject.keywordAuthorLiquid height/volume-
dc.subject.keywordAuthorPower-
dc.subject.keywordAuthorInitial concentration-
dc.subject.keywordAuthorCavitation yield-
Files in This Item
There are no files associated with this item.
Appears in
Collections
Department of Environmental Engineering > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Son, Younggyu photo

Son, Younggyu
College of Engineering (Department of Environmental Engineering)
Read more

Altmetrics

Total Views & Downloads

BROWSE