Micellar enhanced ultrafiltration (MEUF) and activated carbon fibre (ACF) hybrid processes for chromate removal from wastewater
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Bade, Rabindra | - |
dc.contributor.author | Lee, Seung Hwan | - |
dc.contributor.author | Jo, Sungsik | - |
dc.contributor.author | Lee, Hong-Shin | - |
dc.contributor.author | Lee, Sung-eok | - |
dc.date.accessioned | 2023-12-11T10:00:36Z | - |
dc.date.available | 2023-12-11T10:00:36Z | - |
dc.date.issued | 2008-09-15 | - |
dc.identifier.issn | 0011-9164 | - |
dc.identifier.issn | 1873-4464 | - |
dc.identifier.uri | https://scholarworks.bwise.kr/kumoh/handle/2020.sw.kumoh/22263 | - |
dc.description.abstract | Chromate removal from aqueous Solutions by micellar enhanced ultrafiltration (MEUF) at different operating parameters initial retentate pressure, initial permeate flux, initial chromate concentration, pH. and molar ratio of chromate to cetylpyridium chloride (CPC) has been investigated. At the separate experiment for each parameter, with the increase of the initial permeate flux, initial retentate pressure, and molar ratio of chromate to CPC, the removal increased while the permeate flux declined. Considering higher chromate removal efficiency and higher permeate flux, operating initial permeate flux of 43.7 L/m(2).h, chromate to CPC molar ratio of 1:5 and operating initial retentate pressure of 0.14 MPa were found to be the optimum parameters within the experimental conditions. The chromate removal efficiencies were 98.6% and 99.5% respectively for molar ratio of 1:5 and 1: 10 with the corresponding average fluxes of 33.3 L/m(2).h and 24.6 L/m(2).h. The CPC removal efficiencies were only 60.7% and 76.2% respectively. The adsorption capacity of the activated carbon fibre (ACF) was 259 mg/g. With ACF cartridge CPC removal reached above 98%). The MEUF-ACF hybrid process has the removal efficiencies of 99.9%, and 98.6% respectively for CPC and chromate with the corresponding effluent concentrations of 0.29 mg/L and 0.27 mg/L at the molar ratio of chromate to CPC of 1:5. Two ACF cartridge Units in series have removed CPC efficiently from the wastewater. | - |
dc.format.extent | 15 | - |
dc.language | 영어 | - |
dc.language.iso | ENG | - |
dc.publisher | ELSEVIER SCIENCE BV | - |
dc.title | Micellar enhanced ultrafiltration (MEUF) and activated carbon fibre (ACF) hybrid processes for chromate removal from wastewater | - |
dc.type | Article | - |
dc.publisher.location | 네델란드 | - |
dc.identifier.doi | 10.1016/j.desal.2007.10.015 | - |
dc.identifier.wosid | 000259691100022 | - |
dc.identifier.bibliographicCitation | DESALINATION, v.229, no.1-3, pp 264 - 278 | - |
dc.citation.title | DESALINATION | - |
dc.citation.volume | 229 | - |
dc.citation.number | 1-3 | - |
dc.citation.startPage | 264 | - |
dc.citation.endPage | 278 | - |
dc.type.docType | Article | - |
dc.description.isOpenAccess | N | - |
dc.description.journalRegisteredClass | scie | - |
dc.description.journalRegisteredClass | scopus | - |
dc.relation.journalResearchArea | Engineering | - |
dc.relation.journalResearchArea | Water Resources | - |
dc.relation.journalWebOfScienceCategory | Engineering, Chemical | - |
dc.relation.journalWebOfScienceCategory | Water Resources | - |
dc.subject.keywordPlus | MEMBRANE SEPARATION | - |
dc.subject.keywordPlus | REVERSE-OSMOSIS | - |
dc.subject.keywordPlus | ION REMOVAL | - |
dc.subject.keywordPlus | SURFACTANTS | - |
dc.subject.keywordPlus | CHROMIUM | - |
dc.subject.keywordPlus | METALS | - |
dc.subject.keywordPlus | SYSTEM | - |
dc.subject.keywordAuthor | ultrafiltration membrane | - |
dc.subject.keywordAuthor | micellar enhanced ultrafiltration chromate | - |
dc.subject.keywordAuthor | cetylpyridinium chloride | - |
dc.subject.keywordAuthor | activated carbon fibre | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
350-27, Gumi-daero, Gumi-si, Gyeongsangbuk-do, Republic of Korea (39253)054-478-7170
COPYRIGHT 2020 Kumoh University All Rights Reserved.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.