Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Combined deep CNN-LSTM network-based multitasking learning architecture for noninvasive continuous blood pressure estimation using difference in ECG-PPG features

Full metadata record
DC Field Value Language
dc.contributor.authorJeong, Da Un-
dc.contributor.authorLim, Ki Moo-
dc.date.accessioned2023-12-11T18:30:46Z-
dc.date.available2023-12-11T18:30:46Z-
dc.date.issued2021-06-29-
dc.identifier.issn2045-2322-
dc.identifier.urihttps://scholarworks.bwise.kr/kumoh/handle/2020.sw.kumoh/25827-
dc.description.abstractThe pulse arrival time (PAT), the difference between the R-peak time of electrocardiogram (ECG) signal and the systolic peak of photoplethysmography (PPG) signal, is an indicator that enables noninvasive and continuous blood pressure estimation. However, it is difficult to accurately measure PAT from ECG and PPG signals because they have inconsistent shapes owing to patient-specific physical characteristics, pathological conditions, and movements. Accordingly, complex preprocessing is required to estimate blood pressure based on PAT. In this paper, as an alternative solution, we propose a noninvasive continuous algorithm using the difference between ECG and PPG as a new feature that can include PAT information. The proposed algorithm is a deep CNN-LSTM-based multitasking machine learning model that outputs simultaneous prediction results of systolic (SBP) and diastolic blood pressures (DBP). We used a total of 48 patients on the PhysioNet website by splitting them into 38 patients for training and 10 patients for testing. The prediction accuracies of SBP and DBP were 0.0 +/- 1.6 mmHg and 0.2 +/- 1.3 mmHg, respectively. Even though the proposed model was assessed with only 10 patients, this result was satisfied with three guidelines, which are the BHS, AAMI, and IEEE standards for blood pressure measurement devices.-
dc.language영어-
dc.language.isoENG-
dc.publisherNATURE RESEARCH-
dc.titleCombined deep CNN-LSTM network-based multitasking learning architecture for noninvasive continuous blood pressure estimation using difference in ECG-PPG features-
dc.typeArticle-
dc.publisher.location독일-
dc.identifier.doi10.1038/s41598-021-92997-0-
dc.identifier.wosid000671783200037-
dc.identifier.bibliographicCitationSCIENTIFIC REPORTS, v.11, no.1-
dc.citation.titleSCIENTIFIC REPORTS-
dc.citation.volume11-
dc.citation.number1-
dc.type.docTypeArticle-
dc.description.isOpenAccessN-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
dc.relation.journalResearchAreaScience & Technology - Other Topics-
dc.relation.journalWebOfScienceCategoryMultidisciplinary Sciences-
dc.subject.keywordPlusTIME-
Files in This Item
There are no files associated with this item.
Appears in
Collections
Department of Medical IT Convergence Engineering > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Altmetrics

Total Views & Downloads

BROWSE