공동주택에서 바닥복사냉방의 간헐운전시 열성능 평가
DC Field | Value | Language |
---|---|---|
dc.contributor.author | 조영흠 | - |
dc.contributor.author | 김광우 | - |
dc.contributor.author | 임재한 | - |
dc.contributor.author | 여명석 | - |
dc.date.accessioned | 2024-02-27T15:30:47Z | - |
dc.date.available | 2024-02-27T15:30:47Z | - |
dc.date.issued | 2012-03 | - |
dc.identifier.issn | 1976-6483 | - |
dc.identifier.uri | https://scholarworks.bwise.kr/kumoh/handle/2020.sw.kumoh/27812 | - |
dc.description.abstract | In this study, the operation strategy of the radiant floor cooling at intermittent cooling operation is evaluated in terms of indoor environmental conditions through simulations using the TRNSYS. The result of this study show that simulations on various situations while intermittently operated for cooling in an actual apartment building, the operation strategy is proposed that system and control method for cooling are varied with period. Specifically, when there are no people in the room, rooms were operated by only radiant floor cooling system by using cooling storage and people are occupied, rooms were operated by dehumidification and supplementary cooling device with radiant floor cooling system. In the intermittent cooling, it is possible to operate the radiant floor cooling without other supplementary cooling device if pre-cooling using the large thermal capacity of structure was conducted. And it has the advantage over the PAC economically if we are considering initial cost. | - |
dc.format.extent | 7 | - |
dc.language | 한국어 | - |
dc.language.iso | KOR | - |
dc.publisher | 한국건축친환경설비학회 | - |
dc.title | 공동주택에서 바닥복사냉방의 간헐운전시 열성능 평가 | - |
dc.title.alternative | Thermal Performance Evaluation of Radiant Floor Cooling in Apartment Buildings at Intermittent Cooling Operation | - |
dc.type | Article | - |
dc.publisher.location | 대한민국 | - |
dc.identifier.bibliographicCitation | 한국건축친환경설비학회 논문집, v.6, no.3, pp 174 - 180 | - |
dc.citation.title | 한국건축친환경설비학회 논문집 | - |
dc.citation.volume | 6 | - |
dc.citation.number | 3 | - |
dc.citation.startPage | 174 | - |
dc.citation.endPage | 180 | - |
dc.identifier.kciid | ART001700563 | - |
dc.description.isOpenAccess | N | - |
dc.description.journalRegisteredClass | kciCandi | - |
dc.subject.keywordAuthor | Radiant floor cooling | - |
dc.subject.keywordAuthor | Apartment buildings | - |
dc.subject.keywordAuthor | Intermittent Cooling Operation | - |
dc.subject.keywordAuthor | Performance Evaluation | - |
dc.subject.keywordAuthor | 바닥복사냉방 | - |
dc.subject.keywordAuthor | 공동주택 | - |
dc.subject.keywordAuthor | 간헐운전 | - |
dc.subject.keywordAuthor | 성능평가 | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
350-27, Gumi-daero, Gumi-si, Gyeongsangbuk-do, Republic of Korea (39253)054-478-7170
COPYRIGHT 2020 Kumoh University All Rights Reserved.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.