Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Arterial Distension Monitoring Scheme Using FPGA-Based Inference Machine in Ultrasound Scanner Circuit System

Full metadata record
DC Field Value Language
dc.contributor.authorLee, Young-Chan-
dc.contributor.authorKo, Doo-Hyeon-
dc.contributor.authorSon, Min-Hyeong-
dc.contributor.authorYang, Se-Hwan-
dc.contributor.authorUm, Ji-Yong-
dc.date.accessioned2024-07-12T08:30:23Z-
dc.date.available2024-07-12T08:30:23Z-
dc.date.issued2024-06-
dc.identifier.issn1932-4545-
dc.identifier.issn1940-9990-
dc.identifier.urihttps://scholarworks.bwise.kr/kumoh/handle/2020.sw.kumoh/28783-
dc.description.abstractThis paper presents an arterial distension monitoring scheme using a field-programmable gate array (FPGA)-based inference machine in an ultrasound scanner circuit system. An arterial distension monitoring requires a precise positioning of an ultrasound probe on an artery as a prerequisite. The proposed arterial distension monitoring scheme is based on a finite state machine that incorporates sequential support vector machines (SVMs) to assist in both coarse and fine adjustments of probe position. The SVMs sequentially perform recognitions of ultrasonic A-mode echo pattern for a human carotid artery. By employing sequential SVMs in combination with convolution and average pooling, the number of features for the inference machine is significantly reduced, resulting in less utilization of hardware resources in FPGA. The proposed arterial distension monitoring scheme was implemented in an FPGA (Artix7) with a resource utilization percentage less than 9.3%. To demonstrate the proposed scheme, we implemented a customized ultrasound scanner consisting of a single-element transducer, an FPGA, and analog interface circuits with discrete chips. In measurements, we set virtual coordinates on a human neck for 9 human subjects. The achieved accuracy of probe positioning inference is 88%, and the Pearson coefficient (r) of arterial distension estimation is 0.838.-
dc.format.extent12-
dc.language영어-
dc.language.isoENG-
dc.publisherIEEE-INST ELECTRICAL ELECTRONICS ENGINEERS INC-
dc.titleArterial Distension Monitoring Scheme Using FPGA-Based Inference Machine in Ultrasound Scanner Circuit System-
dc.typeArticle-
dc.publisher.location미국-
dc.identifier.doi10.1109/TBCAS.2024.3363134-
dc.identifier.scopusid2-s2.0-85184813823-
dc.identifier.wosid001236736100013-
dc.identifier.bibliographicCitationIEEE TRANSACTIONS ON BIOMEDICAL CIRCUITS AND SYSTEMS, v.18, no.3, pp 702 - 713-
dc.citation.titleIEEE TRANSACTIONS ON BIOMEDICAL CIRCUITS AND SYSTEMS-
dc.citation.volume18-
dc.citation.number3-
dc.citation.startPage702-
dc.citation.endPage713-
dc.type.docTypeArticle-
dc.description.isOpenAccessN-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
dc.relation.journalResearchAreaEngineering-
dc.relation.journalWebOfScienceCategoryEngineering, Biomedical-
dc.relation.journalWebOfScienceCategoryEngineering, Electrical & Electronic-
dc.subject.keywordPlusPRESSURE-
dc.subject.keywordAuthorProbes-
dc.subject.keywordAuthorUltrasonic imaging-
dc.subject.keywordAuthorMonitoring-
dc.subject.keywordAuthorSupport vector machines-
dc.subject.keywordAuthorBiomedical monitoring-
dc.subject.keywordAuthorBlood pressure-
dc.subject.keywordAuthorField programmable gate arrays-
dc.subject.keywordAuthorArterial distension monitoring-
dc.subject.keywordAuthorfield programmable gate array (FPGA)-
dc.subject.keywordAuthorsequential support vector machine (SVM)-
dc.subject.keywordAuthorultrasound probe positioning-
dc.subject.keywordAuthorultrasound scanner-
Files in This Item
There are no files associated with this item.
Appears in
Collections
Department of Medical IT Convergence Engineering > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Altmetrics

Total Views & Downloads

BROWSE