열전소자를 활용한 하이브리드 제습시스템의 구성에 관한 기초적 연구
DC Field | Value | Language |
---|---|---|
dc.contributor.author | 류성룡 | - |
dc.contributor.author | 염호진 | - |
dc.contributor.author | 이현제 | - |
dc.contributor.author | 조현 | - |
dc.date.available | 2020-04-24T10:25:41Z | - |
dc.date.created | 2020-03-31 | - |
dc.date.issued | 2018 | - |
dc.identifier.issn | 1976-6483 | - |
dc.identifier.uri | https://scholarworks.bwise.kr/kumoh/handle/2020.sw.kumoh/357 | - |
dc.description.abstract | In this paper, the hybrid dehumidification system using thermoelectric device is based on the idea of utilizing waste heat from the heat dissipation side of thermoelectric device as a heat source to regenerate chemical desiccant. We would like to apply this system to spaces required dehumidification due to continuous moisture generation or local high humidity in the houses. And, we want to confirm the possibility of developing the hybrid dehumidification system that combines passive dehumidification using chemical desiccant with active dehumidification using thermoelectric device. | - |
dc.language | 한국어 | - |
dc.language.iso | ko | - |
dc.publisher | 한국건축친환경설비학회 | - |
dc.title | 열전소자를 활용한 하이브리드 제습시스템의 구성에 관한 기초적 연구 | - |
dc.title.alternative | A Fundamental Study on the Composition for the Hybrid Dehumidification System Using Thermoelectric Device | - |
dc.type | Article | - |
dc.contributor.affiliatedAuthor | 류성룡 | - |
dc.identifier.bibliographicCitation | 한국건축친환경설비학회 논문집, v.12, no.6, pp.618 - 626 | - |
dc.citation.title | 한국건축친환경설비학회 논문집 | - |
dc.citation.volume | 12 | - |
dc.citation.number | 6 | - |
dc.citation.startPage | 618 | - |
dc.citation.endPage | 626 | - |
dc.type.rims | ART | - |
dc.identifier.kciid | ART002419211 | - |
dc.description.journalClass | 2 | - |
dc.subject.keywordAuthor | 열전소자 | - |
dc.subject.keywordAuthor | 화학제습 | - |
dc.subject.keywordAuthor | 하이브리드 제습시스템 | - |
dc.subject.keywordAuthor | 재생 | - |
dc.subject.keywordAuthor | Thermoelectric Device | - |
dc.subject.keywordAuthor | Chemical Dehumidification | - |
dc.subject.keywordAuthor | Hybrid Dehumidification System | - |
dc.subject.keywordAuthor | Regeneration | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
350-27, Gumi-daero, Gumi-si, Gyeongsangbuk-do, Republic of Korea (39253)054-478-7170
COPYRIGHT 2020 Kumoh University All Rights Reserved.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.