THE VALUE OF GROSS VISUAL ASSESSMENT OF SPECIMEN ADEQUACY FOR LIQUID-BASED CYTOLOGY DURING ULTRASOUND-GUIDED, FINE-NEEDLE ASPIRATION OF THYROID NODULES
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Moon, Won-Jin | - |
dc.contributor.author | Baek, Jung Hwan | - |
dc.contributor.author | Choi, Jin Woo | - |
dc.contributor.author | Kim, Young Joong | - |
dc.contributor.author | Ha, Eun Ju | - |
dc.contributor.author | Lim, Hyun Kyung | - |
dc.contributor.author | Song, Dong Eun | - |
dc.contributor.author | Lee, Jeong Hyun | - |
dc.contributor.author | Shong, Young Kee | - |
dc.date.accessioned | 2021-08-11T19:25:42Z | - |
dc.date.available | 2021-08-11T19:25:42Z | - |
dc.date.issued | 2015-11 | - |
dc.identifier.issn | 1530-891X | - |
dc.identifier.issn | 1934-2403 | - |
dc.identifier.uri | https://scholarworks.bwise.kr/sch/handle/2021.sw.sch/10155 | - |
dc.description.abstract | Objective: Major problems of fine-needle aspiration (FNA) of thyroid nodules arise due to nondiagnostic results caused by inadequately obtained FNA specimens. The purpose of this study was to evaluate the value of visual assessment of liquid-based cytology specimens during FNA of thyroid nodules for predicting sampling adequacy. Methods: For 3 months, visual assessment of FNA specimens was used for 534 consecutive nodules in 534 patients. The FNA specimens were visually graded immediately following aspiration for each nodule, and the visual grades were classified into 2 categories: inadequate (<6 cell groups) and adequate (>6 cell groups). The cytology results were classified as diagnostic or nondiagnostic based on the Bethesda system. We compared the ultrasound features and FNA characteristics between the diagnostic and nondiagnostic results. Multiple logistic regression analysis was used to determine factors independently predictive of nondiagnostic results. We also evaluated the interobserver agreement regarding the visual assessment. Results: Visual assessment was feasible in all patients, and the nondiagnostic rate was 11.6% (62 of 534). Nondiagnostic results were more frequent in the inadequate visual assessment group (38.1%) than in the adequate visual assessment group (10.5%) (P = .001). Independent predictive factors for nondiagnostic results were inadequate visual assessment (odds ratio, 5.18), >50% vascularity (odds ratio, 3.98), and macrocalcification (odds ratio, 3.60). Interobserver agreement for the prediction of visual assessment was good (. value, 0.767; P < .001). Conclusion: Immediate visual assessment of a specimen during FNA of a thyroid nodule is a feasible method for predicting sampling adequacy. | - |
dc.format.extent | 8 | - |
dc.language | 영어 | - |
dc.language.iso | ENG | - |
dc.publisher | American Association of Clinical Endocrinology | - |
dc.title | THE VALUE OF GROSS VISUAL ASSESSMENT OF SPECIMEN ADEQUACY FOR LIQUID-BASED CYTOLOGY DURING ULTRASOUND-GUIDED, FINE-NEEDLE ASPIRATION OF THYROID NODULES | - |
dc.type | Article | - |
dc.publisher.location | 미국 | - |
dc.identifier.doi | 10.4158/EP14529.OR | - |
dc.identifier.scopusid | 2-s2.0-84979819216 | - |
dc.identifier.wosid | 000377966000004 | - |
dc.identifier.bibliographicCitation | Endocrine Practice, v.21, no.11, pp 1219 - 1226 | - |
dc.citation.title | Endocrine Practice | - |
dc.citation.volume | 21 | - |
dc.citation.number | 11 | - |
dc.citation.startPage | 1219 | - |
dc.citation.endPage | 1226 | - |
dc.type.docType | Article | - |
dc.description.isOpenAccess | N | - |
dc.description.journalRegisteredClass | scie | - |
dc.description.journalRegisteredClass | scopus | - |
dc.relation.journalResearchArea | Endocrinology & Metabolism | - |
dc.relation.journalWebOfScienceCategory | Endocrinology & Metabolism | - |
dc.subject.keywordPlus | BETHESDA SYSTEM | - |
dc.subject.keywordPlus | DIAGNOSTIC-ACCURACY | - |
dc.subject.keywordPlus | CONVENTIONAL SMEARS | - |
dc.subject.keywordPlus | COST-EFFECTIVENESS | - |
dc.subject.keywordPlus | ON-SITE | - |
dc.subject.keywordPlus | BIOPSY | - |
dc.subject.keywordPlus | CYTOPATHOLOGY | - |
dc.subject.keywordPlus | MANAGEMENT | - |
dc.subject.keywordPlus | FEATURES | - |
dc.subject.keywordPlus | LESIONS | - |
dc.subject.keywordAuthor | specimen adequacy | - |
dc.subject.keywordAuthor | liguid-based cytology | - |
dc.subject.keywordAuthor | fine needle aspiration | - |
dc.subject.keywordAuthor | thyroid nodule | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
(31538) 22, Soonchunhyang-ro, Asan-si, Chungcheongnam-do, Republic of Korea+82-41-530-1114
COPYRIGHT 2021 by SOONCHUNHYANG UNIVERSITY ALL RIGHTS RESERVED.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.