Comparison of the photon charge between water and solid phantom depending on depth

Authors
Hong, J. W.Lee, H. K.Cho, J. H.
Issue Date
Jul-2015
Publisher
Novim Medical Radiation Institute
Keywords
Water phantom; solid phantom; charge; absorbed dose
Citation
International Journal of Radiation Research, v.13, no.3, pp 229 - 234
Pages
6
Journal Title
International Journal of Radiation Research
Volume
13
Number
3
Start Page
229
End Page
234
URI
https://scholarworks.bwise.kr/sch/handle/2021.sw.sch/10531
DOI
10.7508/ijrr.2015.03.005
ISSN
2345-4229
Abstract
Background: This study assessed the clinical usefulness of the solid phantom, which may compensate for the disadvantages of the water phantom, by comparing the radiological doses between the two depending on their depths. Materials and Methods: The experimental equipment used was a linear accelerator for medical use, water phantom, solid phantom, Farmer type ion chamber and electrometer. The distance between the ray source and the center of the ion chamber was fixed to a SAD of 100 cm during the experiment. The field size was 10 x 10 cm(2) and the radiation energies of the photon rays were 6 MV and 15 MV. The depth interval was 1cm (range 1-10 cm) for each energy. The rela naive deviation ratio of the water phantom to the solid phantom was calculated. Results: The measurement at 100 MU was performed more than five times to calculate the average charge and absorbed dose, and the relative deviation was analyzed based on the water phantom. The results obtained at depths from 1 to 10 cm were 0.034%, 0.457%, -0.167%, 0.011%, 0.117%, 0.271%, 0.349%, 0.709%, 0.376% and 0.611% at 6 MV and those obtained at 15 MV were 1.199%, 0.033%, 0.166%, 0.496%, 0.556%, 0.705%, 0.656%, 1.071%, 0.7% and 1.057%, respectively. Conclusion: In conclusion, the solid phantom is useful and may complement the disadvantages of the water phantom, including the % me required for its installation and errors in the measurement depth, and may precisely measure the radiological dose.
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Engineering > Department of Computer Science and Engineering > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Lee, HAE KAG photo

Lee, HAE KAG
College of Engineering (Department of Computer Science and Engineering)
Read more

Altmetrics

Total Views & Downloads

BROWSE