Detailed Information

Cited 0 time in webofscience Cited 11 time in scopus
Metadata Downloads

Comparison between Ultrasonography and Computed Tomography for Detecting the Pyramidal Lobe of the Thyroid Gland: A Prospective Multicenter Study

Full metadata record
DC Field Value Language
dc.contributor.authorKim, Dong Wook-
dc.contributor.authorJung, So Lyung-
dc.contributor.authorKim, Jinna-
dc.contributor.authorRyu, Ji Hwa-
dc.contributor.authorSung, Jin Yong-
dc.contributor.authorLim, Hyun Kyung-
dc.date.accessioned2021-08-11T20:43:58Z-
dc.date.available2021-08-11T20:43:58Z-
dc.date.issued2015-03-
dc.identifier.issn1229-6929-
dc.identifier.issn2005-8330-
dc.identifier.urihttps://scholarworks.bwise.kr/sch/handle/2021.sw.sch/10832-
dc.description.abstractObjective: To compare the detection rates of the pyramidal lobe of the thyroid gland (TPL) using ultrasonography (US) and computed tomography (CT) in a prospective multi-center study. Materials and Methods: We enrolled 582 patients who underwent neck CT at six institutions. Each radiologist prospectively evaluated the presence and features of TPLs on thyroid US. Radiologists were divided into two groups according to their previous experience in detecting TPL on US or CT. The same radiologist also retrospectively assessed CT findings, blinded to the corresponding US findings. Results: The pyramidal lobe of the thyroid glands were detected in 230 cases (39.5%) on US and in 276 cases (47.6%) on CT. The TPL detection rate at the six institutions ranged from 22.0% to 59% for US and from 34.1% to 59% using CT. There were significant differences between US and CT in the detection rate, length, anteroposterior diameter, volume, and superior extent of TPL (p <= 0.027). The TPL detection rates on both US and CT (p < 0.001) differed significantly according to the experience level of the radiologists. When the CT result was used as a reference standard, the sensitivity, specificity, positive and negative predictive values, as well as the accuracy of US for TPL detection were 72.6%, 91.5%, 89.3%, 77.3%, and 82.1%, respectively. Conclusion: Our prospective multicenter study revealed that US could detect TPL with relatively high diagnostic accuracy compared to CT. Because the detection rate of TPL varied significantly according to the radiologists' level of experience, careful inspection is necessary to avoid imaging pitfalls and ensure appropriate evaluation of TPL on both US and CT.-
dc.format.extent8-
dc.language영어-
dc.language.isoENG-
dc.publisher대한영상의학회-
dc.titleComparison between Ultrasonography and Computed Tomography for Detecting the Pyramidal Lobe of the Thyroid Gland: A Prospective Multicenter Study-
dc.typeArticle-
dc.publisher.location대한민국-
dc.identifier.doi10.3348/kjr.2015.16.2.402-
dc.identifier.scopusid2-s2.0-84923917613-
dc.identifier.wosid000351424800017-
dc.identifier.bibliographicCitationKorean Journal of Radiology, v.16, no.2, pp 402 - 409-
dc.citation.titleKorean Journal of Radiology-
dc.citation.volume16-
dc.citation.number2-
dc.citation.startPage402-
dc.citation.endPage409-
dc.type.docTypeArticle-
dc.identifier.kciidART001980615-
dc.description.isOpenAccessN-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
dc.description.journalRegisteredClasskci-
dc.relation.journalResearchAreaRadiology, Nuclear Medicine & Medical Imaging-
dc.relation.journalWebOfScienceCategoryRadiology, Nuclear Medicine & Medical Imaging-
dc.subject.keywordPlusSINGLE-CENTER-
dc.subject.keywordPlusULTRASOUND-
dc.subject.keywordPlusSURGERY-
dc.subject.keywordPlusPREVALENCE-
dc.subject.keywordPlusMANAGEMENT-
dc.subject.keywordPlusSTATEMENT-
dc.subject.keywordPlusPAPILLARY-
dc.subject.keywordPlusFEATURES-
dc.subject.keywordPlusANATOMY-
dc.subject.keywordPlusCANCER-
dc.subject.keywordAuthorThyroid-
dc.subject.keywordAuthorVariation-
dc.subject.keywordAuthorPyramidal lobe-
dc.subject.keywordAuthorUltrasonography-
dc.subject.keywordAuthorComputed tomography-
dc.subject.keywordAuthorAnatomy-
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Medicine > Department of Radiology > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Lim, Hyun Kyung photo

Lim, Hyun Kyung
College of Medicine (Department of Radiology)
Read more

Altmetrics

Total Views & Downloads

BROWSE