Analysis of radiation risk to patients from intraoperative use of the mobile X-ray system (C-arm)
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Lee, Yang-Sub | - |
dc.contributor.author | Lee, Hae-Kag | - |
dc.contributor.author | Cho, Jae-Hwan | - |
dc.contributor.author | Kim, Ham-Gyum | - |
dc.date.accessioned | 2021-08-11T20:46:20Z | - |
dc.date.available | 2021-08-11T20:46:20Z | - |
dc.date.issued | 2015-01 | - |
dc.identifier.issn | 1735-1995 | - |
dc.identifier.issn | 1735-7136 | - |
dc.identifier.uri | https://scholarworks.bwise.kr/sch/handle/2021.sw.sch/10978 | - |
dc.description.abstract | The aim of this study was to investigate clinical applications of mobile C-arms and consequent radiation risk, to increase medical attention on radiation protection, and to provide basic data for safe radiation use in the operating room. Materials and Methods: In this study, a total of 374 surgical operations, conducted using a portable fluoroscopic X-ray system from January to March of 2013, were analyzed. Dose summaries produced by the General Electric C-arm and data elements in digital imaging and communications in the medicine header of Ziehm C-arm, fluoroscopy time were used to obtain dose-area product (DAP) and effective dose. Corresponding mean and maximum values were calculated, and the resulting data on the frequency of application, fluoroscopy time, DAP, and effective dose were compared and analyzed in terms of surgical specialty and operation types. Results: Orthopedic surgery was the most frequent with 165 cases (44.1%). The highest DAP value and effective dose were found in liver transplant among surgical specialty fields, with mean values of 2.90 +/- 3.76 mGy.m(2) and 58 +/- 75.2 mSv, respectively (P = 0.0001). The highest DAP value and effective dose were observed in intra-operative mesenteric portography among types of surgery, showing mean values of 2.90 +/- 3.81 mGy.m(2) and 58.03 +/- 76.24 mSv, respectively (P = 0.0001). Conclusion: Because DAP varies significantly across surgical specialties and types of operation, aggressive efforts to understand the effects of radiation dose is critical for radiation protection from intra-operative use of mobile C-arms. | - |
dc.format.extent | 6 | - |
dc.language | 영어 | - |
dc.language.iso | ENG | - |
dc.publisher | Isfahan University of Medical Sciences | - |
dc.title | Analysis of radiation risk to patients from intraoperative use of the mobile X-ray system (C-arm) | - |
dc.type | Article | - |
dc.publisher.location | 인도 | - |
dc.identifier.scopusid | 2-s2.0-84924987389 | - |
dc.identifier.wosid | 000352209400002 | - |
dc.identifier.bibliographicCitation | Journal of Research in Medical Sciences, v.20, no.1, pp 7 - 12 | - |
dc.citation.title | Journal of Research in Medical Sciences | - |
dc.citation.volume | 20 | - |
dc.citation.number | 1 | - |
dc.citation.startPage | 7 | - |
dc.citation.endPage | 12 | - |
dc.type.docType | Article | - |
dc.description.isOpenAccess | N | - |
dc.description.journalRegisteredClass | scie | - |
dc.description.journalRegisteredClass | scopus | - |
dc.relation.journalResearchArea | General & Internal Medicine | - |
dc.relation.journalWebOfScienceCategory | Medicine, General & Internal | - |
dc.subject.keywordPlus | DOSE-AREA PRODUCT | - |
dc.subject.keywordPlus | EXPOSURE | - |
dc.subject.keywordAuthor | Dose | - |
dc.subject.keywordAuthor | rea product | - |
dc.subject.keywordAuthor | effective dose | - |
dc.subject.keywordAuthor | mobile C-arm | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
(31538) 22, Soonchunhyang-ro, Asan-si, Chungcheongnam-do, Republic of Korea+82-41-530-1114
COPYRIGHT 2021 by SOONCHUNHYANG UNIVERSITY ALL RIGHTS RESERVED.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.