비숙련자에서 매킨토시 후두경과 일회용 후두경을 이용한 기관 삽관의 비교: 마네킹연구

Full metadata record
DC Field Value Language
dc.contributor.author이은형-
dc.contributor.author최재형-
dc.contributor.author임훈-
dc.contributor.author조영순-
dc.contributor.author이정원-
dc.contributor.author이보라-
dc.date.accessioned2021-08-11T20:47:37Z-
dc.date.available2021-08-11T20:47:37Z-
dc.date.created2021-06-17-
dc.date.issued2015-
dc.identifier.issn1226-4334-
dc.identifier.urihttps://scholarworks.bwise.kr/sch/handle/2021.sw.sch/11083-
dc.description.abstractPurpose: Disposable one piece laryngoscope (DOL), which probably carries a lower risk of infection than conventional reusable ones, is the only device which has received approval by the Korean Ministry of Food and Drug safety. In the current study, we evaluated the effectiveness and usefulness of the conventional Macintosh laryngoscope (MAC) and DOL in inexperienced personnel. Methods: A randomized crossover trial was designed. Ninety seven participants (Medical students, Paramedic students) were enrolled and performed endotracheal intubation with MAC and DOL in Manikin (SimMan Laedal Medical Corporation, Stravanger; Norway). Cormack- Lehane grade, the number of attempts, time required for intubation, and dental compression were measured to evaluate the effectiveness. The participants were given a questionnaire survey on the usefulness of laryngoscopes (easier to use, lightness, brightness, manageable to use, delivering power, safer for patients, intense to use). Results: Regarding the aspect of effectiveness, a significant difference in dental compression was observed between DOL and MAC (p=0.011). Others showed no significant differences. Regarding the aspect of usefulness, DOL was superior to MAC except in delivering power. Conclusion: The DOL appears to be a reasonable device for use in emergency airway management. It should be verified for effectiveness and usefulness of newly developed equipment in emergency airway management because it is directly related to life.-
dc.language한국어-
dc.language.isoko-
dc.publisher대한응급의학회-
dc.title비숙련자에서 매킨토시 후두경과 일회용 후두경을 이용한 기관 삽관의 비교: 마네킹연구-
dc.title.alternativeComparison of Tracheal Intubation Using the Macintosh Laryngoscope Versus the Disposable Laryngoscope by Inexperienced Personnel: A Manikin Study-
dc.typeArticle-
dc.contributor.affiliatedAuthor최재형-
dc.contributor.affiliatedAuthor임훈-
dc.contributor.affiliatedAuthor조영순-
dc.contributor.affiliatedAuthor이정원-
dc.identifier.bibliographicCitation대한응급의학회지, v.26, no.6, pp.563 - 570-
dc.relation.isPartOf대한응급의학회지-
dc.citation.title대한응급의학회지-
dc.citation.volume26-
dc.citation.number6-
dc.citation.startPage563-
dc.citation.endPage570-
dc.type.rimsART-
dc.identifier.kciidART002067529-
dc.description.journalClass2-
dc.description.journalRegisteredClasskci-
dc.subject.keywordAuthorDisposable equipment-
dc.subject.keywordAuthorLaryngoscopes-
dc.subject.keywordAuthorIntubation-
dc.subject.keywordAuthorAirway management-
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Medicine > Department of Emergency Medicine > 1. Journal Articles
College of Medicine > Department of Emergency Medicine > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Cho, Young Soon photo

Cho, Young Soon
College of Medicine (Department of Emergency Medicine)
Read more

Altmetrics

Total Views & Downloads

BROWSE