Detailed Information

Cited 0 time in webofscience Cited 4 time in scopus
Metadata Downloads

Evaluation of automatic exposure control system chamber for the dose optimization when examining pelvic in digital radiography

Full metadata record
DC Field Value Language
dc.contributor.authorKim, Sung-Chul-
dc.contributor.authorLee, Hae-Kag-
dc.contributor.authorLee, Yang-Sub-
dc.contributor.authorCho, Jae-Hwan-
dc.date.accessioned2021-08-11T21:44:56Z-
dc.date.available2021-08-11T21:44:56Z-
dc.date.issued2015-
dc.identifier.issn0895-3996-
dc.identifier.issn1095-9114-
dc.identifier.urihttps://scholarworks.bwise.kr/sch/handle/2021.sw.sch/11526-
dc.description.abstractWe found a way to optimize the image quality and reduce the exposure dose of patients through the proper activity combination of the automatic exposure control system chamber for the dose optimization when examining the pelvic anteroposterior side using the phantom of the human body standard model. We set 7 combinations of the chamber of automatic exposure control system. The effective dose was yielded by measuring five times for each according to the activity combination of the chamber for the dose measurement. Five radiologists with more than five years of experience evaluated the image through picture archiving and communication system using double blind test while classifying the 6 anatomical sites into 3-point level (improper, proper, perfect). When only one central chamber was activated, the effective dose was found to be the highest level, 0.287 mSv; and lowest when only the top left chamber was used, 0.165 mSv. After the subjective evaluation by five panel members on the pelvic image was completed, there was no statistically meaningful difference between the 7 chamber combinations, and all had good image quality. When testing the pelvic anteroposterior side with digital radiography, we were able to reduce the exposure dose of patients using the combination of the top right side of or the top two of the chamber.-
dc.format.extent10-
dc.language영어-
dc.language.isoENG-
dc.publisherIOS Press-
dc.titleEvaluation of automatic exposure control system chamber for the dose optimization when examining pelvic in digital radiography-
dc.typeArticle-
dc.publisher.location네델란드-
dc.identifier.doi10.3233/XST-150492-
dc.identifier.scopusid2-s2.0-84931024966-
dc.identifier.wosid000355981500004-
dc.identifier.bibliographicCitationJournal of X-Ray Science and Technology, v.23, no.3, pp 321 - 330-
dc.citation.titleJournal of X-Ray Science and Technology-
dc.citation.volume23-
dc.citation.number3-
dc.citation.startPage321-
dc.citation.endPage330-
dc.type.docTypeArticle-
dc.description.isOpenAccessN-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
dc.relation.journalResearchAreaInstruments & Instrumentation-
dc.relation.journalResearchAreaOptics-
dc.relation.journalResearchAreaPhysics-
dc.relation.journalWebOfScienceCategoryInstruments & Instrumentation-
dc.relation.journalWebOfScienceCategoryOptics-
dc.relation.journalWebOfScienceCategoryPhysics, Applied-
dc.subject.keywordPlusCOMPUTED RADIOGRAPHY-
dc.subject.keywordPlusIMAGE QUALITY-
dc.subject.keywordAuthorDigital radiography-
dc.subject.keywordAuthorauto exposure control-
dc.subject.keywordAuthorchamber-
dc.subject.keywordAuthordose optimization-
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Engineering > Department of Computer Science and Engineering > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Lee, HAE KAG photo

Lee, HAE KAG
College of Engineering (Department of Computer Science and Engineering)
Read more

Altmetrics

Total Views & Downloads

BROWSE