Detailed Information

Cited 0 time in webofscience Cited 22 time in scopus
Metadata Downloads

Comparison of Three-Dimensional Isotropic and Two-Dimensional. Conventional Indirect MR Arthrography for the Diagnosis of Rotator Cuff Tears

Authors
Lee, Ji HyunYoon, Young CheolJee, SukkyungKwon, Jong WonCha, Jang GyuYoo, Jae Chul
Issue Date
Nov-2014
Publisher
대한영상의학회
Keywords
Magnetic resonance imaging; Indirect MR arthrography; Isotropic; Shoulder; Rotator cuff
Citation
Korean Journal of Radiology, v.15, no.6, pp 771 - 780
Pages
10
Journal Title
Korean Journal of Radiology
Volume
15
Number
6
Start Page
771
End Page
780
URI
https://scholarworks.bwise.kr/sch/handle/2021.sw.sch/11729
DOI
10.3348/kjr.2014.15.6.771
ISSN
1229-6929
2005-8330
Abstract
Objective: To compare the accuracy between a three-dimensional (3D) indirect isotropic T1-weighted fast spin-echo (FSE) magnetic resonance (MR) arthrography and a conventional two-dimensional (2D) T1-weighted sequences of indirect MR arthrography for diagnosing rotator cuff tears. Materials and Methods: The study was approved by our Institutional Review Board. In total, 205 patients who had undergone indirect shoulder MR arthrography followed by arthroscopic surgery for 206 shoulders were included in this study. Both conventional 2D T1-weighted FSE sequences and 3D isotropic T1-weighted FSE sequence were performed in all patients. Two radiologists evaluated the images for the presence of full- or partial-thickness tears in the supraspinatus-infraspinatus (SSP-ISP) tendons and tears in the subscapularis (SSC) tendons. Using the arthroscopic findings as the reference standard, the diagnostic performances of both methods were analyzed by the area under the receiver operating characteristic curve (AUC). Results: Arthroscopy confirmed 165 SSP-ISP tendon tears and 103 SSC tendon tears. For diagnosing SSP-ISP tendon tears, the AUC values were 0.964 and 0.989 for the 2D sequences and 3D T1-weighted FSE sequence, respectively, in reader I and 0.947 and 0.963, respectively, in reader II. The AUC values for diagnosing SSC tendon tears were 0.921 and 0.925, respectively, for reader I and 0.856 and 0.860, respectively, for reader II. There was no significant difference between the AUC values of the 2D and 3D sequences in either reader for either type of tear. Conclusion: 3D indirect isotropic MR arthrography with FSE sequence and the conventional 2D arthrography are not significantly different in terms of accuracy for diagnosing rotator cuff tears.
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Medicine > Department of Radiology > 1. Journal Articles

qrcode