공압식 박동형 심실보조장치의 공압관 내 압력 측정을 통한 박출량 추정
DC Field | Value | Language |
---|---|---|
dc.contributor.author | 김영일 | - |
dc.contributor.author | 허균 | - |
dc.contributor.author | 강성민 | - |
dc.contributor.author | 최성욱 | - |
dc.date.accessioned | 2021-08-11T23:44:50Z | - |
dc.date.available | 2021-08-11T23:44:50Z | - |
dc.date.issued | 2014 | - |
dc.identifier.issn | 1229-0807 | - |
dc.identifier.issn | 2288-9396 | - |
dc.identifier.uri | https://scholarworks.bwise.kr/sch/handle/2021.sw.sch/12710 | - |
dc.description.abstract | A Ventricular assist device (VAD) is one of the most efficient treatments to raise the survivability of theend stage heart failure patient. However, some of LVAD patients have died for the failures and improper control ofLVAD. To detect critical dangers in LVAD, the monitoring methods of LVAD outflow have been requested, becauseit can be affected by patient’s hemodynamic states and abnormal conditions of LVAD. In the case of an external pulsatileLVAD, the air movement through the air line can be used to estimate LVAD outflow. In this study, the air movementin the air-line of the extracorporeal pulsatile LVAD was measured with a differential pressure sensor betweendifferent points. The precise estimation of air movement could be achieved by additional measurement of air pressure. In a series of in-vitro experiments, the LVAD outflow were changed according to the afterload of LVAD andthe differential pressure of LVAD didn’t have close correlation with the LVAD outflow that were measured with anultrasonic flowmeter at the same time. However, new precise estimation with the data from differential pressure andone point pressure in the air-line showed higher correlations with LVAD outflow. | - |
dc.format.extent | 6 | - |
dc.language | 한국어 | - |
dc.language.iso | KOR | - |
dc.publisher | 대한의용생체공학회 | - |
dc.title | 공압식 박동형 심실보조장치의 공압관 내 압력 측정을 통한 박출량 추정 | - |
dc.title.alternative | Estimation of Ventricular Assist Device Outflow with the Pressures in Air Pressure Line | - |
dc.type | Article | - |
dc.publisher.location | 대한민국 | - |
dc.identifier.doi | 10.9718/JBER.2014.35.5.119 | - |
dc.identifier.bibliographicCitation | 의공학회지, v.35, no.5, pp 119 - 124 | - |
dc.citation.title | 의공학회지 | - |
dc.citation.volume | 35 | - |
dc.citation.number | 5 | - |
dc.citation.startPage | 119 | - |
dc.citation.endPage | 124 | - |
dc.identifier.kciid | ART001923211 | - |
dc.description.isOpenAccess | N | - |
dc.description.journalRegisteredClass | kci | - |
dc.subject.keywordAuthor | Pneumatic Pulsatile Ventricular Assist Device | - |
dc.subject.keywordAuthor | VAD Pump Outflow | - |
dc.subject.keywordAuthor | Air Pressure | - |
dc.subject.keywordAuthor | Air Flow | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
(31538) 22, Soonchunhyang-ro, Asan-si, Chungcheongnam-do, Republic of Korea+82-41-530-1114
COPYRIGHT 2021 by SOONCHUNHYANG UNIVERSITY ALL RIGHTS RESERVED.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.