dc.description.abstract | Purpose: This study aimed to investigate efficient approaches for determining internal target volume (ITV) from four-dimensional computed tomography (4D CT) images used in stereotactic body radiotherapy (SBRT) for patients with early-stage non-small cell lung cancer (NSCLC). Materials and Methods: 4D CT images were analyzed for 15 patients who received SBRT for stage I NSCLC. Three different ITVs were determined as follows: combining clinical target volume (CTV) from all 10 respiratory phases (ITV10Phases); combining CTV from four respiratory phases, including two extreme phases (0% and 50%) plus two intermediate phases (20% and 70%) (ITV4Phases); and combining CTV from two extreme phases (ITV2Phases). The matching index (MI) of ITV4Phases and ITV(2Phase)s was defined as the ratio of ITV4Phases and ITV2Phases, respectively, to the ITV10Phases. The tumor motion index (TMI) was defined as the ratio of ITV10Phases to CTVmean, which was the mean of 10 CTVs delineated on 10 respiratory phases. Results: The ITVs were significantly different in the order of ITV10Phases, ITV4Phases, and ITV2Phases (all p < 0.05). The MI of ITV(4Phase)s was significantly higher than that of ITV2Phases (p < 0.001). The MI of ITV4Phases was inversely related to TMI (r = -0.569, p = 0.034). In a subgroup with low TMI (n = 7), ITV4Phases was not statistically different from ITV10Phases (p = 0.192) and its MI was significantly higher than that of ITV2Phases (p = 0.016). Conclusion: The ITV4Phases may be an efficient approach alternative to optimal ITV10Phases in SBRT for early-stage NSCLC with less tumor motion. | - |
dc.format.extent | 5 | - |
dc.language | 영어 | - |
dc.language.iso | ENG | - |
dc.publisher | Korean Society for Therapeutic Radiology and Oncology | - |
dc.title | Efficient approach for determining four-dimensional computed tomography-based internal target volume in stereotactic radiotherapy of lung cancer | - |
dc.type | Article | - |
dc.publisher.location | 대한민국 | - |
dc.identifier.doi | 10.3857/roj.2013.31.4.247 | - |
dc.identifier.scopusid | 2-s2.0-84893288196 | - |
dc.identifier.wosid | 000420361500011 | - |
dc.identifier.bibliographicCitation | Radiation Oncology Journal, v.31, no.4, pp 247 - 251 | - |
dc.citation.title | Radiation Oncology Journal | - |
dc.citation.volume | 31 | - |
dc.citation.number | 4 | - |
dc.citation.startPage | 247 | - |
dc.citation.endPage | 251 | - |
dc.type.docType | Article | - |
dc.identifier.kciid | ART001836564 | - |
dc.description.isOpenAccess | N | - |
dc.description.journalRegisteredClass | scopus | - |
dc.description.journalRegisteredClass | kciCandi | - |
dc.relation.journalResearchArea | Oncology | - |
dc.relation.journalWebOfScienceCategory | Oncology | - |
dc.subject.keywordAuthor | Four-dimensional computed tomography | - |
dc.subject.keywordAuthor | Internal target volume | - |
dc.subject.keywordAuthor | Lung cancer | - |
dc.subject.keywordAuthor | Stereotactic body radiotherapy | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
(31538) 22, Soonchunhyang-ro, Asan-si, Chungcheongnam-do, Republic of Korea+82-41-530-1114
COPYRIGHT 2021 by SOONCHUNHYANG UNIVERSITY ALL RIGHTS RESERVED.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.