Fusion Imaging-Guided Percutaneous Biopsy of Focal Hepatic Lesions With Poor Conspicuity on Conventional Sonography

Full metadata record
DC Field Value Language
dc.contributor.authorPark, Hyun Jeong-
dc.contributor.authorLee, Min Woo-
dc.contributor.authorLee, Mi Hee-
dc.contributor.authorHwang, Jiyoung-
dc.contributor.authorKang, Tae Wook-
dc.contributor.authorLim, Sanghyeok-
dc.contributor.authorRhim, Hyunchul-
dc.contributor.authorLim, Hyo K.-
dc.date.accessioned2021-08-12T00:46:45Z-
dc.date.available2021-08-12T00:46:45Z-
dc.date.issued2013-09-
dc.identifier.issn0278-4297-
dc.identifier.issn1550-9613-
dc.identifier.urihttps://scholarworks.bwise.kr/sch/handle/2021.sw.sch/13407-
dc.description.abstractObjectives-The purpose of this study was to evaluate the effectiveness of real-time fusion imaging (sonography combined with computed tomography or magnetic resonance imaging) for percutaneous sonographically guided biopsy of focal hepatic lesions with poor sonographic conspicuity. Methods-This study was conducted as a retrospective analysis of a prospective database and was approved by the Institutional Review Board. Patients who had target lesions with poor conspicuity on B-mode sonography for percutaneous biopsy were enrolled in the study. Lesion conspicuity was assessed by conventional B-mode sonography first and then by fusion imaging later in the same session. We compared lesion conspicuity and detection rates between B-mode sonography and fusion imaging and evaluated how many cases of initially invisible lesions on B-mode sonography became visible on fusion imaging. The technical success rate was evaluated on the basis of the final diagnoses, which were established by pathologic examination of the biopsy specimens as well as follow-up clinical and radiologic examinations. Results-A total of 22 patients were enrolled in the study. On fusion imaging, lesion conspicuity was increased in 63.6% of focal hepatic lesions (14 of 22). Moreover, 66.7% of lesions (6 of 9) that were invisible on B-mode sonography became visible on fusion imaging. The true-positive detection rate was significantly different between B-mode sonography and fusion imaging (9 of 22 versus 19 of 22; P = .0044). Percutaneous biopsy was performed for all lesions, including 3 target lesions that were invisible even on fusion imaging. The technical success rate was 95.5% (21 of 22). Conclusions-Fusion imaging is effective for percutaneous biopsy of focal hepatic lesions with poor sonographic conspicuity.-
dc.format.extent8-
dc.language영어-
dc.language.isoENG-
dc.publisherAmerican Institute for Ultrasound in Medicine-
dc.titleFusion Imaging-Guided Percutaneous Biopsy of Focal Hepatic Lesions With Poor Conspicuity on Conventional Sonography-
dc.typeArticle-
dc.publisher.location미국-
dc.identifier.doi10.7863/ultra.32.9.1557-
dc.identifier.scopusid2-s2.0-84883366911-
dc.identifier.wosid000323810200005-
dc.identifier.bibliographicCitationJournal of Ultrasound in Medicine, v.32, no.9, pp 1557 - 1564-
dc.citation.titleJournal of Ultrasound in Medicine-
dc.citation.volume32-
dc.citation.number9-
dc.citation.startPage1557-
dc.citation.endPage1564-
dc.type.docTypeArticle-
dc.description.isOpenAccessN-
dc.description.journalRegisteredClasssci-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
dc.relation.journalResearchAreaAcoustics-
dc.relation.journalResearchAreaRadiology, Nuclear Medicine & Medical Imaging-
dc.relation.journalWebOfScienceCategoryAcoustics-
dc.relation.journalWebOfScienceCategoryRadiology, Nuclear Medicine & Medical Imaging-
dc.subject.keywordPlusCONTRAST-ENHANCED SONOGRAPHY-
dc.subject.keywordPlusVIRTUAL CT SONOGRAPHY-
dc.subject.keywordPlusHEPATOCELLULAR-CARCINOMA-
dc.subject.keywordPlusRADIOFREQUENCY ABLATION-
dc.subject.keywordPlusGUIDANCE-
dc.subject.keywordPlusULTRASONOGRAPHY-
dc.subject.keywordPlusULTRASOUND-
dc.subject.keywordPlusUTILITY-
dc.subject.keywordAuthorbiopsy-
dc.subject.keywordAuthorconspicuity-
dc.subject.keywordAuthorfusion imaging-
dc.subject.keywordAuthorliver-
dc.subject.keywordAuthorsonography-
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Medicine > Department of Radiology > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Hwang, Ji young photo

Hwang, Ji young
College of Medicine (Department of Radiology)
Read more

Altmetrics

Total Views & Downloads

BROWSE