Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

슬레이트 지붕의 설치년도와 면적에 따른 공기 및 유출 빗물 중의 석면 농도

Full metadata record
DC Field Value Language
dc.contributor.author장봉기-
dc.contributor.author류제영-
dc.contributor.author탁현욱-
dc.contributor.author송수진-
dc.contributor.author이종화-
dc.contributor.author이강호-
dc.contributor.author최재호-
dc.date.accessioned2021-08-12T01:44:17Z-
dc.date.available2021-08-12T01:44:17Z-
dc.date.created2021-06-17-
dc.date.issued2013-
dc.identifier.issn2384-132x-
dc.identifier.urihttps://scholarworks.bwise.kr/sch/handle/2021.sw.sch/14218-
dc.description.abstractObjectives: The purpose of this study is to analyze the number and influence factors of asbestos fibers in the air of farmhouses with asbestos cement slate roofing, as well as in rainwater per unit area of the asbestos cement slate roofing. Methods: At a distance of 1 m from the end of asbestos cement slate roofing in 20 farmhouses, the asbestos fiber in the air was collected three times on a clear day downwind from the prevailing wind. Rainwater falling from the slate roofing was collected four times with a 1.05-m rainwater pipe on a rainy day at the 20 farmhouses, filtered with a MCE filter, and analyzed with a phase contrast microscope. Results: The geometric mean of the number of asbestos fibers in the air of farmhouses with slate roofing was 0.11 fiber/L, and no samples exceeded the recommended standard of 10 fiber/L. As a result of multiple regression analysis, a factor which gave a significant influence to the asbestos fiber content in the air was the gross area of slate roofing at the target farmhouses. The number of asbestos fibers included in rainwater collected per 1 m2 of slate roofing was 1,753 fiber/L∙m2. As a result of multiple regression analysis, the number of asbestos fibers contained in rainwater per 1 m2 of slate showed a significantly higher tendency as the year of slate roofing installation at the target farmhouses receded. Conclusions: It was confirmed for the first time in Korea that asbestos from asbestos cement slate roofing scatters into the air.-
dc.language한국어-
dc.language.isoko-
dc.publisher한국산업보건학회-
dc.title슬레이트 지붕의 설치년도와 면적에 따른 공기 및 유출 빗물 중의 석면 농도-
dc.title.alternativeAsbestos Concentrations of Ambient Air and Drained Rainwater from Slate Roofing by Construction Year and the Roof Area-
dc.typeArticle-
dc.contributor.affiliatedAuthor장봉기-
dc.identifier.bibliographicCitation한국산업보건학회지, v.23, no.3, pp.196 - 204-
dc.relation.isPartOf한국산업보건학회지-
dc.citation.title한국산업보건학회지-
dc.citation.volume23-
dc.citation.number3-
dc.citation.startPage196-
dc.citation.endPage204-
dc.type.rimsART-
dc.identifier.kciidART001808998-
dc.description.journalClass2-
dc.description.journalRegisteredClasskci-
dc.subject.keywordAuthorAsbestos-
dc.subject.keywordAuthorSlate roofing-
dc.subject.keywordAuthorAirborne-
dc.subject.keywordAuthorRainwater-
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Natural Sciences > Department of Environmental Health Science > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Jang, Bong Ki photo

Jang, Bong Ki
College of Natural Sciences (Department of Environmental Health Science)
Read more

Altmetrics

Total Views & Downloads

BROWSE