흉부 전산화단층촬영에서 우연히 발견된 유방 병변의 평가
DC Field | Value | Language |
---|---|---|
dc.contributor.author | 김재현 | - |
dc.contributor.author | 장윤우 | - |
dc.contributor.author | 이은혜 | - |
dc.contributor.author | 황정화 | - |
dc.contributor.author | 김형환 | - |
dc.contributor.author | 양승부 | - |
dc.date.accessioned | 2021-08-12T02:24:41Z | - |
dc.date.available | 2021-08-12T02:24:41Z | - |
dc.date.issued | 2013 | - |
dc.identifier.issn | 1738-2637 | - |
dc.identifier.issn | 2288-2928 | - |
dc.identifier.uri | https://scholarworks.bwise.kr/sch/handle/2021.sw.sch/14516 | - |
dc.description.abstract | Purpose: To evaluate the significance of incidentally detected breast lesions on a chest CT scan. Materials and Methods: Thirty-six incidental breast lesions in 26 patients were detected on a chest CT scan and were correlated with breast sonography, retrospectively. Among them, twenty-four breast lesions in 20 patients that were correlated with chest CT and sonography were available to pathology or follow up sonography. The CT findings were compared with sonographic findings according to the pathologic results. Results: Incidentally detected breast lesions on a chest CT scan were correlated with sonography in 86% (31/36). Among 24 lesions that were available to pathology or follow up sonography, seven (29.2%) lesions were malignant and 17 (70.8%) lesions were benign. CT revealed a significant difference between benign and malignant lesions in terms of shape and margin (p = 0.007; p = 0.008, respectively). The CT findings were well correlated with sonographic findings in shape and margin (p = 0.001, respectively). Conclusion: Incidentally detected breast lesions on chest CT can be correlated with sonography. An irregular shape or a non-circumscribed margin of breast lesions on a CT scan can be considered as a suggestive sign of malignancy. | - |
dc.format.extent | 7 | - |
dc.language | 영어 | - |
dc.language.iso | ENG | - |
dc.publisher | 대한영상의학회 | - |
dc.title | 흉부 전산화단층촬영에서 우연히 발견된 유방 병변의 평가 | - |
dc.title.alternative | Evaluation of the Significance of Incidental Breast Lesions Detected by Chest CT | - |
dc.type | Article | - |
dc.publisher.location | 대한민국 | - |
dc.identifier.bibliographicCitation | 대한영상의학회지, v.68, no.3, pp 229 - 235 | - |
dc.citation.title | 대한영상의학회지 | - |
dc.citation.volume | 68 | - |
dc.citation.number | 3 | - |
dc.citation.startPage | 229 | - |
dc.citation.endPage | 235 | - |
dc.identifier.kciid | ART001750543 | - |
dc.description.isOpenAccess | N | - |
dc.description.journalRegisteredClass | kci | - |
dc.subject.keywordAuthor | Breast | - |
dc.subject.keywordAuthor | Chest CT | - |
dc.subject.keywordAuthor | Incidentally Detected Lesion | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
(31538) 22, Soonchunhyang-ro, Asan-si, Chungcheongnam-do, Republic of Korea+82-41-530-1114
COPYRIGHT 2021 by SOONCHUNHYANG UNIVERSITY ALL RIGHTS RESERVED.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.