Detailed Information

Cited 0 time in webofscience Cited 8 time in scopus
Metadata Downloads

Comparison of the diagnostic performances of two protocols of hand perfusion scintigraphy for Raynaud's phenomenon

Authors
Lee, Jeong WonJeong, Woo SeongLee, Sang MeeKim, Jinseok
Issue Date
Oct-2012
Publisher
Lippincott Williams & Wilkins Ltd.
Keywords
diagnostic performance; Raynaud's phenomenon; Tc-99m-methylene diphosphonate scintigraphy
Citation
Nuclear Medicine Communications, v.33, no.10, pp 1032 - 1038
Pages
7
Journal Title
Nuclear Medicine Communications
Volume
33
Number
10
Start Page
1032
End Page
1038
URI
https://scholarworks.bwise.kr/sch/handle/2021.sw.sch/14798
DOI
10.1097/MNM.0b013e3283567492
ISSN
0143-3636
1473-5628
Abstract
Objective The aim of this study was to compare the diagnostic performances of two hand perfusion scintigraphy protocols for diagnosing Raynaud's phenomenon (RP). Methods We enrolled 130 patients who underwent hand perfusion scintigraphy for suspected RP and 40 normal controls. Of these, 66 patients (group A) and 25 normal controls underwent Tc-99m-methylene diphosphonate hand perfusion scintigraphy without one-hand chilling, and the finger-to-palm ratio (FPR) was calculated. The remaining 64 patients (group B) and 15 normal controls underwent Tc-99m-methylene diphosphonate hand perfusion scintigraphy with one-hand chilling, and three parameters (the chilled-to-ambient hand ratios of the first peak height, initial slope, and blood pool uptake) were calculated. Results Forty-eight and 47 patients were clinically diagnosed with RP in groups A and B, respectively. In group A, patients with RP had significantly lower FPRs compared with those without RP, and the receiver operating characteristic curve analysis showed that an FPR of 0.51 was the best cutoff value for diagnosing RP, with a sensitivity of 63% and a specificity of 83%. In group B, the three aforementioned parameters differed significantly (lower or higher) between patients with and without RP. The receiver operating characteristic curve analysis provided highly sensitive and specific results for all three parameters. The initial slope ratio showed the highest sensitivity of 87% and a specificity of 88% when using cutoff values of 0.78 and 1.25. Conclusion Although both protocols for hand perfusion scintigraphy showed high specificity for diagnosing RP, the protocol with one-hand chilling showed higher diagnostic ability compared with that without one-hand chilling. Nucl Med Commun 33:1032-1038 (C) 2012 Wolters Kluwer Health vertical bar Lippincott Williams & Wilkins.
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Medicine > Department of Radiology > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Lee, Sang Mi photo

Lee, Sang Mi
College of Medicine (핵의학교실(천안))
Read more

Altmetrics

Total Views & Downloads

BROWSE