Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

The Qualitative Analysis of Single Shot Fast Spin Echo (SSFSE) and Maximum Intensity Projection (MIP) on Magnetic Resonance Cholangiopancreatography

Full metadata record
DC Field Value Language
dc.contributor.authorPark, Cheol-Soo-
dc.contributor.authorCho, Jae-Hwan-
dc.contributor.authorLee, Hae-Kag-
dc.contributor.authorDong, Kyung-Rae-
dc.contributor.authorChung, Woon-Kwan-
dc.contributor.authorSeok, Jong-Min-
dc.contributor.authorHan, Man-Seok-
dc.contributor.authorLee, Sun-Yeob-
dc.contributor.authorGoo, Eun-Hoe-
dc.contributor.authorKim, Eng-Chan-
dc.date.accessioned2021-08-12T03:24:54Z-
dc.date.available2021-08-12T03:24:54Z-
dc.date.issued2012-06-
dc.identifier.issn1226-1750-
dc.identifier.issn2233-6656-
dc.identifier.urihttps://scholarworks.bwise.kr/sch/handle/2021.sw.sch/15122-
dc.description.abstract3-dimensional magnetic resonance cholangiopancreatography (MRCP) images reconstructed using the maximum intensity projection technique were analyzed qualitatively in patients diagnosed with pancreatobiliary diseases to determine their diagnostic utility. Single shot fast spin echo (SSFSE), fast spin echo (FSE) and 3-dimensional reconstructive images were acquired from 20 patients diagnosed histologically with pancreatobiliary diseases using a 3.0T MR scanner. According to qualitative analysis, the fast spin echo images and 3-dimensional reconstructed images of the hepatic duct, gall bladder and common bile duct had a higher signal to noise ratio (SNR) than the single shot fast spin echo images. Fast spin echo images and 3-dimensional reconstructed images did not show any differences. The contrast to noise ratio of the hepatic duct, gallbladder and common bile duct on the fast spin echo images and 3-dimensional reconstructed images was higher than that of the single shot fast spin echo images. The fast spin echo images and 3-dimensional reconstructed images showed similar quality.-
dc.format.extent7-
dc.language영어-
dc.language.isoENG-
dc.publisher한국자기학회-
dc.titleThe Qualitative Analysis of Single Shot Fast Spin Echo (SSFSE) and Maximum Intensity Projection (MIP) on Magnetic Resonance Cholangiopancreatography-
dc.typeArticle-
dc.publisher.location대한민국-
dc.identifier.doi10.4283/JMAG.2012.17.2.138-
dc.identifier.scopusid2-s2.0-84864011203-
dc.identifier.wosid000305864500012-
dc.identifier.bibliographicCitationJournal of Magnetics, v.17, no.2, pp 138 - 144-
dc.citation.titleJournal of Magnetics-
dc.citation.volume17-
dc.citation.number2-
dc.citation.startPage138-
dc.citation.endPage144-
dc.type.docTypeArticle-
dc.identifier.kciidART001673385-
dc.description.isOpenAccessN-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
dc.description.journalRegisteredClasskci-
dc.relation.journalResearchAreaMaterials Science-
dc.relation.journalResearchAreaPhysics-
dc.relation.journalWebOfScienceCategoryMaterials Science, Multidisciplinary-
dc.relation.journalWebOfScienceCategoryPhysics, Applied-
dc.relation.journalWebOfScienceCategoryPhysics, Condensed Matter-
dc.subject.keywordPlusENDOSCOPIC RETROGRADE CHOLANGIOGRAPHY-
dc.subject.keywordPlusMR CHOLANGIOGRAPHY-
dc.subject.keywordPlusERCP-
dc.subject.keywordAuthorMRCP-
dc.subject.keywordAuthorSSFSE-
dc.subject.keywordAuthorFSE-
dc.subject.keywordAuthor3D reconstruction image-
dc.subject.keywordAuthorSNR-
dc.subject.keywordAuthorCNR-
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Engineering > Department of Computer Science and Engineering > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Lee, HAE KAG photo

Lee, HAE KAG
College of Engineering (Department of Computer Science and Engineering)
Read more

Altmetrics

Total Views & Downloads

BROWSE