Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

The Effect of Electrocautery around the Patellar Rim in Patellar Non-Resurfacing Total Knee Arthroplasty

Full metadata record
DC Field Value Language
dc.contributor.author임수재-
dc.contributor.authorSang Hyok Lee-
dc.contributor.authorMun Suk Jang-
dc.contributor.authorWook Joong Kim-
dc.contributor.authorHee Kyung Kang-
dc.date.accessioned2021-08-12T04:25:47Z-
dc.date.available2021-08-12T04:25:47Z-
dc.date.issued2012-
dc.identifier.issn1225-1623-
dc.identifier.issn2234-2451-
dc.identifier.urihttps://scholarworks.bwise.kr/sch/handle/2021.sw.sch/15792-
dc.description.abstractPurpose: The purpose of this study was to evaluate the clinical effect of electrocautery on the reduction of pain in patellar non-resurfacing bilateral total knee arthroplasty. Materials and Methods: A total of 50 patients were enrolled into this study; all patients had undergone bilateral patellar non-resurfacing total knee arthoplasty at our hospital, between January 2007 to December 2008. The minimum follow-up period was 1 year. The electrocautery of the patellar rim was performed randomly on one side only. The clinical results were evaluated between the electrocautery group and the non-electrocautery group based on measures of anterior knee pain, range of motion, American Knee Society clinical rating score, Feller knee score, Western Ontario and McMaster Universities score, and radiographic analysis. Results: There were statistically significant differences between preoperative and postoperative status for all parameters. There were no statistically significant differences noted between the electrocautery group and the non electrocautery group for all parameters. Conclusions: Electrocautery of patellar rim is thought to be less effective in reducing anterior knee pain.-
dc.format.extent4-
dc.language영어-
dc.language.isoENG-
dc.publisher대한슬관절학회-
dc.titleThe Effect of Electrocautery around the Patellar Rim in Patellar Non-Resurfacing Total Knee Arthroplasty-
dc.title.alternativeThe Effect of Electrocautery around the Patellar Rim in Patellar Non-Resurfacing Total Knee Arthroplasty-
dc.typeArticle-
dc.publisher.location영국-
dc.identifier.bibliographicCitationKnee Surgery and Related Research, v.24, no.2, pp 104 - 107-
dc.citation.titleKnee Surgery and Related Research-
dc.citation.volume24-
dc.citation.number2-
dc.citation.startPage104-
dc.citation.endPage107-
dc.identifier.kciidART001664235-
dc.description.isOpenAccessN-
dc.description.journalRegisteredClasskciCandi-
dc.subject.keywordAuthorPatellar rim-
dc.subject.keywordAuthorAnterior knee pain-
dc.subject.keywordAuthorElectrocautery-
dc.subject.keywordAuthorTotal knee arthroplasty.-
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Medicine > Department of Orthopedic Surgery > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher yim, soo jae photo

yim, soo jae
College of Medicine (Department of Orthopedic Surgery)
Read more

Altmetrics

Total Views & Downloads

BROWSE