Detailed Information

Cited 0 time in webofscience Cited 2 time in scopus
Metadata Downloads

Dose assessment according to changes in algorithm in cardiac CT

Full metadata record
DC Field Value Language
dc.contributor.authorJang, H. C.-
dc.contributor.authorCho, J. H.-
dc.contributor.authorLee, H. K.-
dc.contributor.authorHong, I. S.-
dc.contributor.authorCho, M. S.-
dc.contributor.authorPark, C. S.-
dc.contributor.authorLee, S. Y.-
dc.contributor.authorDong, K. R.-
dc.contributor.authorGoo, E. H.-
dc.contributor.authorChung, W. K.-
dc.contributor.authorRyu, Y. H.-
dc.contributor.authorLim, C. S.-
dc.date.accessioned2021-08-12T04:44:39Z-
dc.date.available2021-08-12T04:44:39Z-
dc.date.issued2012-
dc.identifier.issn1042-0150-
dc.identifier.issn1029-4953-
dc.identifier.urihttps://scholarworks.bwise.kr/sch/handle/2021.sw.sch/15983-
dc.description.abstractThe principal objective of this study was to determine the effects of the application of the adaptive statistical iterative reconstruction (ASIR) technique in combination with another two factors (body mass index (BMI) and tube potential) on radiation dose in cardiac computed tomography (CT). For quantitative analysis, regions of interest were positioned on the central region of the great coronary artery, the right coronary artery, and the left anterior descending artery, after which the means and standard deviations of measured CT numbers were obtained. For qualitative analysis, images taken from the major coronary arteries (right coronary, left anterior descending, and left circumflex) were graded on a scale of 1-5, with 5 indicating the best image quality. Effective dose, which was calculated by multiplying the value of the dose length product by a standard conversion factor of 0.017 for the chest, was employed as a measure of radiation exposure dose. In cardiac CT in patients with BMI of less than 25 kg/m(2), the use of 40% ASIR in combination with a low tube potential of 100 kVp resulted in a significant reduction in the radiation dose without compromising diagnostic quality. Additionally, the combination of the 120 kVp protocol and the application of 40% ASIR application for patients with BMI higher than 25 kg/m(2) yielded similar results.-
dc.format.extent11-
dc.language영어-
dc.language.isoENG-
dc.publisherTaylor & Francis-
dc.titleDose assessment according to changes in algorithm in cardiac CT-
dc.typeArticle-
dc.publisher.location영국-
dc.identifier.doi10.1080/10420150.2011.644550-
dc.identifier.scopusid2-s2.0-84862175774-
dc.identifier.wosid000304425500003-
dc.identifier.bibliographicCitationRadiation Effects and Defects in Solids, v.167, no.6, pp 392 - 402-
dc.citation.titleRadiation Effects and Defects in Solids-
dc.citation.volume167-
dc.citation.number6-
dc.citation.startPage392-
dc.citation.endPage402-
dc.type.docTypeArticle-
dc.description.isOpenAccessN-
dc.description.journalRegisteredClasssci-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
dc.relation.journalResearchAreaNuclear Science & Technology-
dc.relation.journalResearchAreaPhysics-
dc.relation.journalWebOfScienceCategoryNuclear Science & Technology-
dc.relation.journalWebOfScienceCategoryPhysics, Fluids & Plasmas-
dc.relation.journalWebOfScienceCategoryPhysics, Condensed Matter-
dc.subject.keywordPlusSTATISTICAL ITERATIVE RECONSTRUCTION-
dc.subject.keywordPlusBODY-MASS INDEX-
dc.subject.keywordPlusCOMPUTED-TOMOGRAPHY-
dc.subject.keywordPlusREDUCTION STRATEGY-
dc.subject.keywordPlusIMAGE QUALITY-
dc.subject.keywordPlusANGIOGRAPHY-
dc.subject.keywordPlusPROTOCOLS-
dc.subject.keywordPlusEXPOSURE-
dc.subject.keywordAuthoradaptive statistical iterative reconstruction-
dc.subject.keywordAuthorBMI-
dc.subject.keywordAuthoreffective dose-
dc.subject.keywordAuthorimage noise-
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Engineering > Department of Computer Science and Engineering > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Hong, In Sik photo

Hong, In Sik
College of Engineering (Department of Computer Science and Engineering)
Read more

Altmetrics

Total Views & Downloads

BROWSE