Detailed Information

Cited 0 time in webofscience Cited 2 time in scopus
Metadata Downloads

Comparison of the Measured Stem Leakage Correction Factor for an Ionization Chamber in Air to the Monte Carlo Simulation

Full metadata record
DC Field Value Language
dc.contributor.authorKweon, Dae Cheol-
dc.contributor.authorLee, Jae-Seung-
dc.contributor.authorGoo, Eun-Hoe-
dc.contributor.authorKim, Moon-Jib-
dc.contributor.authorJung, Jae-Eun-
dc.contributor.authorChung, Woon-Kwan-
dc.contributor.authorDong, Kyung-Rae-
dc.contributor.authorLee, Jin-Kook-
dc.contributor.authorPark, Cheol-Woo-
dc.contributor.authorIm, In-Chul-
dc.date.accessioned2021-08-12T05:44:42Z-
dc.date.available2021-08-12T05:44:42Z-
dc.date.issued2011-05-
dc.identifier.issn0374-4884-
dc.identifier.issn1976-8524-
dc.identifier.urihttps://scholarworks.bwise.kr/sch/handle/2021.sw.sch/16567-
dc.description.abstractStem leakage arises as a consequence of the direct irradiation of a sensitive volume, and the metal stem of the ionization chamber, and the chamber response is likely to be affected by the photons scattered from the chamber stem. These interactions contribute to the apparent measured exposure. Build-up caps were used in the exposure measurement. The stem leakages of PTW model TM 30013 and TM 31010 (vented to air, sensitive volume: 0.6 and 0.125 cm(3)) ionization chambers were measured. High-energy photons generated by a linear accelerator and the sensitive volume of the ionization chamber were measured to examine the stem leakage of the ionization chamber and were compared with the results of a Monte Carlo simulation. As a result, the electrons ejected from the metal stem could were found to collect at the central electrode. The stem leakage correction factor (k(stem, leak)) decreased with increasing photon energy and sensitive volume. The stern of the ionization chamber that scattered photons made the largest contribution to the exposure dose, showing a dependency on the energy of photons and the sensitive volume of the ionization chamber. The stem leakage correction factors were determined within 0.4% according to the length of the stem exposed in repeated measurements for various radiation fields.-
dc.format.extent11-
dc.language영어-
dc.language.isoENG-
dc.publisher한국물리학회-
dc.titleComparison of the Measured Stem Leakage Correction Factor for an Ionization Chamber in Air to the Monte Carlo Simulation-
dc.typeArticle-
dc.publisher.location대한민국-
dc.identifier.doi10.3938/jkps.58.1184-
dc.identifier.scopusid2-s2.0-79957726505-
dc.identifier.wosid000290635700024-
dc.identifier.bibliographicCitationJournal of the Korean Physical Society, v.58, no.5, pp 1184 - 1194-
dc.citation.titleJournal of the Korean Physical Society-
dc.citation.volume58-
dc.citation.number5-
dc.citation.startPage1184-
dc.citation.endPage1194-
dc.type.docTypeArticle-
dc.identifier.kciidART001552554-
dc.description.isOpenAccessN-
dc.description.journalRegisteredClasssci-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
dc.description.journalRegisteredClasskci-
dc.relation.journalResearchAreaPhysics-
dc.relation.journalWebOfScienceCategoryPhysics, Multidisciplinary-
dc.subject.keywordPlusION-CHAMBER-
dc.subject.keywordPlusPHOTON-
dc.subject.keywordPlusBEAM-
dc.subject.keywordPlusRADIOTHERAPY-
dc.subject.keywordPlusCODE-
dc.subject.keywordAuthorStem leakage-
dc.subject.keywordAuthorIonization chamber-
dc.subject.keywordAuthorMonte Carlo simulation-
dc.subject.keywordAuthorBuild-up cap-
dc.subject.keywordAuthorMeasurement-
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Natural Sciences > Department of Physics > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Altmetrics

Total Views & Downloads

BROWSE