Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

단순 방사선에서의 한국인의 정상 근위 대퇴부의 해부학적 측정 : 항회전 근위 대퇴 골수정을 이용한 수술 시 문제점

Full metadata record
DC Field Value Language
dc.contributor.author박종석-
dc.contributor.author김우종-
dc.contributor.author소재완-
dc.contributor.author장병웅-
dc.contributor.author김태헌-
dc.contributor.author서유성-
dc.date.accessioned2021-08-12T06:25:41Z-
dc.date.available2021-08-12T06:25:41Z-
dc.date.created2021-06-17-
dc.date.issued2011-
dc.identifier.issn2287-3260-
dc.identifier.urihttps://scholarworks.bwise.kr/sch/handle/2021.sw.sch/16961-
dc.description.abstractPurpose: We propose to improve the use of Proximal Femoral Nail Anti-rotation in Korea by reporting anatomical measurements of the normal Korean proximal femur. Materials and Methods: A total of 230 patients were enrolled who had all experienced a femoral intertrochanteric fracture and undergone the Proximal Femoral Nail Anti-rotation surgical procedure between February 2007 and April 2011. We measured the neck-shaft angle and endosteal width at the isthmus of a normal femur, and the distance between the greater trochanter and the nail tip of the Proximal Femoral Nail Anti-rotation in post-operative plain radiography. We analyzed the average and standard deviations of the measurements. We also investigated correlations with the patient gender. Results: The average neck-shaft angle and endosteal width at the isthmus were 129.7。(111.0~138.3。) and 14.5 mm (9.7~23.1 mm), respectively. The average protruded nail length was 4.9 mm (1.0~15.0 mm). The femur neck-shaft angle had a correlation ratio with gender (p=0.000). However, the endosteal width at the isthmus level and the protruded nail length had no correlation ratio with gender (p=0.108, 0.573, respectively). Conclusion: Until now, in intertrochanteric fracture operations using Proximal Femoral Nail Anti-rotation, the selection of devices has been extremely limited. Through this study we present the average Korean anatomical neckshaft angle, endosteal width of the femur, and protruding length of the nail tip. We expect that these numerical values can be used in the production of new devices with shorter proximal nails, which would be more appropriates for Koreans.-
dc.language한국어-
dc.language.isoko-
dc.publisher대한고관절학회-
dc.title단순 방사선에서의 한국인의 정상 근위 대퇴부의 해부학적 측정 : 항회전 근위 대퇴 골수정을 이용한 수술 시 문제점-
dc.title.alternativeAnatomical Measurement of Normal Korean Proximal Femur Using Plain Radiography : A Problem when using Proximal Femoral Nail Anti-rotation-
dc.typeArticle-
dc.contributor.affiliatedAuthor소재완-
dc.identifier.bibliographicCitationHip and Pelvis, v.23, no.4, pp.303 - 309-
dc.relation.isPartOfHip and Pelvis-
dc.citation.titleHip and Pelvis-
dc.citation.volume23-
dc.citation.number4-
dc.citation.startPage303-
dc.citation.endPage309-
dc.type.rimsART-
dc.identifier.kciidART001625978-
dc.description.journalClass2-
dc.description.journalRegisteredClasskci-
dc.subject.keywordAuthor대퇴부-
dc.subject.keywordAuthor항회전 대퇴 골수정-
dc.subject.keywordAuthor단순 방사선-
dc.subject.keywordAuthor측정-
dc.subject.keywordAuthorFemur-
dc.subject.keywordAuthorProximal femoral nail anti-rotation-
dc.subject.keywordAuthorPlain radiography-
dc.subject.keywordAuthorMeasure-
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Medicine > Department of Orthopedic Surgery > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Altmetrics

Total Views & Downloads

BROWSE