Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Direct Comparison between Brachial Pressure Obtained by Oscillometric Method and Central Pressure Using Invasive Method

Full metadata record
DC Field Value Language
dc.contributor.author박상호-
dc.contributor.author이성진-
dc.contributor.author김재연-
dc.contributor.author김민정-
dc.contributor.author이지연-
dc.contributor.author조아라-
dc.contributor.author이혁규-
dc.contributor.author이세환-
dc.contributor.author신원용-
dc.contributor.author진동규-
dc.date.accessioned2021-08-12T06:25:57Z-
dc.date.available2021-08-12T06:25:57Z-
dc.date.issued2011-
dc.identifier.issn2233-4289-
dc.identifier.urihttps://scholarworks.bwise.kr/sch/handle/2021.sw.sch/16986-
dc.description.abstractObjective: The importance of central blood pressure evaluation for cardiovascular risk stratification has been emphasized. The aim of this study is to evaluate whether brachial blood pressure obtained by the oscillometric method accurately reflects central blood pressure. Methods: The subjects consisted of 84 consecutive patients with suspected coronary artery disease who underwent cardiac catheterization. Central blood pressure was invasively measured in the origin of the left subclavian artery by using the fluid-filled system,and at the same time, brachial blood pressure in the left upper arm was measured by the oscillometric method. Results: No significant difference was found between central systolic pressure and brachial systolic pressure (144.49±18.84 mmHg vs. 142.44±14.96 mmHg, P=0.063). Bland-Altman analysis accounted for only a small bias of +2.25 mmHg, and the limits of agreement were 24.15 mmHg and -19.65 mmHg. Central diastolic pressure was significantly lower than brachial diastolic pressure (75.80±8.74 mmHg vs. 86.70±10.48 mmHg, P<0.001). Bland-Altman analysis showed a significant bias of -5.45 mmHg, and the limits of agreement were 2.83 mmHg and -13.73 mmHg. Conclusion: These results indicate that central systolic pressure can be directly estimated from brachial systolic pressure using the noninvasive oscillometric method and observed biases seem to remain within the practical range. However, use of the brachial diastolic pressure and pulse pressure measured by the noninvasive oscillometric method is doubtful in clinical practice because of their large biases.-
dc.format.extent7-
dc.language영어-
dc.language.isoENG-
dc.publisher순천향의학연구소-
dc.titleDirect Comparison between Brachial Pressure Obtained by Oscillometric Method and Central Pressure Using Invasive Method-
dc.title.alternativeDirect Comparison between Brachial Pressure Obtained by Oscillometric Method and Central Pressure Using Invasive Method-
dc.typeArticle-
dc.publisher.location대한민국-
dc.identifier.bibliographicCitationSoonchunhyang Medical Science, v.17, no.2, pp 65 - 71-
dc.citation.titleSoonchunhyang Medical Science-
dc.citation.volume17-
dc.citation.number2-
dc.citation.startPage65-
dc.citation.endPage71-
dc.identifier.kciidART001626905-
dc.description.isOpenAccessN-
dc.description.journalRegisteredClasskciCandi-
dc.subject.keywordAuthorBlood pressure-
dc.subject.keywordAuthorOscillometry-
dc.subject.keywordAuthorCoronary artery disease-
dc.subject.keywordAuthorBias-
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Medicine > Department of Internal Medicine > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Lee, Seung Jin photo

Lee, Seung Jin
College of Medicine (Department of Internal Medicine)
Read more

Altmetrics

Total Views & Downloads

BROWSE