Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

심혈관 CT 조영술의 프로토콜 최적화

Full metadata record
DC Field Value Language
dc.contributor.author이해각-
dc.contributor.author유흥준-
dc.contributor.author이선엽-
dc.contributor.author구은회-
dc.contributor.author석종민-
dc.contributor.author한만석-
dc.contributor.author이광성-
dc.contributor.author조재환-
dc.contributor.author김보희-
dc.contributor.author박철수-
dc.date.accessioned2021-08-12T06:45:38Z-
dc.date.available2021-08-12T06:45:38Z-
dc.date.issued2011-
dc.identifier.issn1976-0620-
dc.identifier.issn2384-0633-
dc.identifier.urihttps://scholarworks.bwise.kr/sch/handle/2021.sw.sch/17228-
dc.description.abstractThis research compared and analyzed the heart rate of the patient in which the LVEF value is 40% less than and normal patient. When as for LVEF 40% or less becomes to each heart rate and LVEF in a relation, we can know that the time to reach 100HU hangs long. Therefore, in patients, that is 40% less than, when setting up the Premonitoring delay, we could know to could give 5 primary solid phrases. It is seen that subsequently an addition injected 40cc as to Saline, to all patients by 4cc/sec speeds after injecting the capacity of Scan time x 4cc + 30cc with 4cc/sec speeds. And HR excludes 80 or greater in 40% less than, the contrast agent shows the large-scale difference. In addition, in 40% less than, it could predict that the time difference was big and the contrast agent was already out in the Left ventricle Wash- when the contrast agent reached 100HU and Scan was started There is a wide difference between under 40% LVEF and normal. when starting scan from low LVEF patients. So, Injection contrast media protocol Should be determined to CCTA . And then In case of low LVEF is recommended to more low Pitch than routine Pitch because we should reduce scan failed in accordance with low LVEF.-
dc.format.extent8-
dc.language한국어-
dc.language.isoKOR-
dc.publisher한국방사선학회-
dc.title심혈관 CT 조영술의 프로토콜 최적화-
dc.title.alternativeProtocol Optimization of Coronary CT Angiography-
dc.typeArticle-
dc.publisher.location대한민국-
dc.identifier.bibliographicCitation한국방사선학회논문지, v.5, no.2, pp 51 - 58-
dc.citation.title한국방사선학회논문지-
dc.citation.volume5-
dc.citation.number2-
dc.citation.startPage51-
dc.citation.endPage58-
dc.identifier.kciidART001545859-
dc.description.isOpenAccessN-
dc.description.journalRegisteredClasskciCandi-
dc.subject.keywordAuthorDual source computed tomography-
dc.subject.keywordAuthorCoronary CT Angiogrphy-
dc.subject.keywordAuthorLVEF-
dc.subject.keywordAuthor이중선원 CT-
dc.subject.keywordAuthor관상동맥 조영술-
dc.subject.keywordAuthor좌심실 구혈률-
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Engineering > Department of Computer Science and Engineering > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Lee, HAE KAG photo

Lee, HAE KAG
College of Engineering (Department of Computer Science and Engineering)
Read more

Altmetrics

Total Views & Downloads

BROWSE