Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

내시경과 선택적 도뇨관 풍선을 이용한 안와하벽복원술

Full metadata record
DC Field Value Language
dc.contributor.author최환준-
dc.contributor.author이주철-
dc.contributor.author이형교-
dc.contributor.author김준혁-
dc.date.accessioned2021-08-12T06:47:11Z-
dc.date.available2021-08-12T06:47:11Z-
dc.date.issued2011-
dc.identifier.issn2234-6163-
dc.identifier.issn2234-6171-
dc.identifier.urihttps://scholarworks.bwise.kr/sch/handle/2021.sw.sch/17346-
dc.description.abstractPurpose: Blow - out fractures can be reduced using various methods. The orbital reconstruction technique using a balloon under endoscopic control has advantages over other methods. However, this method has some problems too, such as postoperative follow - up, management of the balloon catheter, and reduction of the posterior orbital floor. Thus, we developed a simple, effective method for orbital floor reduction that involves molding and shaping the antral balloon catheter. Methods: A 0, 30, or 70°, 4 - mm endoscope was placed though a two - point, 5 - mm maxillary antrostomy. The balloon catheter is placed directly at the orbital apex to reconstruct the anterior shelf (spherical shape), while it is turned in a U - shape towards the anterior maxilla for the posterior shelf (elliptical shape). Orbital floor defects, compound or comminuted fractures are reconstructed with alloplastic materials through an open lid incision under endoscopic control. Results: This technique was applied in ten patients with orbital floor fractures: five anterior shelf and five posterior shelf fractures. Four of the patients had zygomatico - orbital fractures, while the rest had isolated orbital floor fractures. Two patients were given porous polyethylene implants (Synpor^Ⓡ) and three underwent reconstruction with a resorbable mesh plate. No complication associated with this technique was identified. Conclusion: The freestyle placement and selection of a urinary balloon catheter under endoscopic control and the preoperative estimation of the volume enhanced the stabilization of the orbital contour. This method improves the adaptation of the orbital floor without the risk of injuring the surrounding orbital contents, dissecting blindly, or using sharp traction. One drawback of this method is the discomfort the patient experiences from the catheter during treatment.-
dc.format.extent8-
dc.language한국어-
dc.language.isoKOR-
dc.publisher대한성형외과학회-
dc.title내시경과 선택적 도뇨관 풍선을 이용한 안와하벽복원술-
dc.title.alternativeOrbital Floor Reconstruction Using Endoscope and Selected Urethral Balloon Catheter-
dc.typeArticle-
dc.publisher.location대한민국-
dc.identifier.bibliographicCitationArchives of Plastic Surgery, v.38, no.1, pp 35 - 42-
dc.citation.titleArchives of Plastic Surgery-
dc.citation.volume38-
dc.citation.number1-
dc.citation.startPage35-
dc.citation.endPage42-
dc.identifier.kciidART001519418-
dc.description.isOpenAccessN-
dc.description.journalRegisteredClasskci-
dc.subject.keywordAuthorBlow - out fracture-
dc.subject.keywordAuthorEndoscope-
dc.subject.keywordAuthorOrbital.-
dc.subject.keywordAuthorBlow - out fracture-
dc.subject.keywordAuthorEndoscope-
dc.subject.keywordAuthorOrbital.-
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Medicine > Department of Plastic Surgery > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Kim, Jun hyuk photo

Kim, Jun hyuk
College of Medicine (Department of Plastic Surgery)
Read more

Altmetrics

Total Views & Downloads

BROWSE