Comparison of four manikins and fresh frozen cadaver models for direct laryngoscopic orotracheal intubation training

Full metadata record
DC Field Value Language
dc.contributor.authorYang, J. H.-
dc.contributor.authorKim, Y-M-
dc.contributor.authorChung, H. S.-
dc.contributor.authorCho, J.-
dc.contributor.authorLee, H-M-
dc.contributor.authorKang, G-H-
dc.contributor.authorKim, E-C-
dc.contributor.authorLim, T.-
dc.contributor.authorCho, Y. S.-
dc.date.accessioned2021-08-12T07:25:42Z-
dc.date.available2021-08-12T07:25:42Z-
dc.date.issued2010-01-
dc.identifier.issn1472-0205-
dc.identifier.issn1472-0213-
dc.identifier.urihttps://scholarworks.bwise.kr/sch/handle/2021.sw.sch/18107-
dc.description.abstractObjective: To compare the acceptability and preference between manikin models and fresh frozen cadaver (FFC) for direct laryngoscopic orotracheal intubation training. Methods: In this prospective crossover trial, participants in the airway workshop performed direct laryngoscopic orotracheal intubation on four airway training manikins: Airway Management Trainer (Ambu, St Ives, UK), Airway Trainer (Laerdal, Medical, Stavanger, Norway), Airsim (Trucorp, Belfast, Northern Ireland) and "Bill 1" (VBM, Sulz, Germany), and FFC. Participants were asked to access the following: reality of jaw mobility, difficulty with mouth opening, reality of neck flexibility, difficulty with intubation, overall model reality and model preference for each model using a visual analogue scale (VAS) of 0 10 cm. The VAS scores for each model were compared. Results: Fifty-six participants were included in the study. The FFC had a highest VAS score for reality of jaw mobility, overall reality and preference of model. Trucorp manikin and Laerdal manikin followed cadaver. There were no significant statistical differences between Trucorp manikin and Laerdal manikin. In difficulty with mouth opening and difficulty with intubation, Trucorp manikin had the lowest VAS score. Conclusion: The FFC is a more realistic and preferred model for direct laryngoscopic orotracheal intubation training. Trucorp and Laerdal manikin can be used as alternative models.-
dc.format.extent4-
dc.language영어-
dc.language.isoENG-
dc.publisherBMJ Publishing Group-
dc.titleComparison of four manikins and fresh frozen cadaver models for direct laryngoscopic orotracheal intubation training-
dc.typeArticle-
dc.publisher.location영국-
dc.identifier.doi10.1136/emj.2008.066456-
dc.identifier.wosid000272991000005-
dc.identifier.bibliographicCitationEmergency Medicine Journal, v.27, no.1, pp 13 - 16-
dc.citation.titleEmergency Medicine Journal-
dc.citation.volume27-
dc.citation.number1-
dc.citation.startPage13-
dc.citation.endPage16-
dc.type.docTypeArticle-
dc.description.isOpenAccessN-
dc.description.journalRegisteredClasssci-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
dc.relation.journalResearchAreaEmergency Medicine-
dc.relation.journalWebOfScienceCategoryEmergency Medicine-
dc.subject.keywordPlusAIRWAY MANAGEMENT-
dc.subject.keywordPlusPROCEDURAL SKILLS-
dc.subject.keywordPlusEMERGENCY-
dc.subject.keywordPlusWORKSHOP-
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Medicine > Department of Emergency Medicine > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Cho, Young Soon photo

Cho, Young Soon
College of Medicine (Department of Emergency Medicine)
Read more

Altmetrics

Total Views & Downloads

BROWSE