Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

연부 조직에 잔류된 금속성 및 비금속성 이물질 Computed Tomography 계수의 임상적 의의The Clinical Significance of Hounsfield Number of Metallic and Non-Metallic Foreign Bodies in the Soft Tissue

Other Titles
The Clinical Significance of Hounsfield Number of Metallic and Non-Metallic Foreign Bodies in the Soft Tissue
Authors
최환준이한정강상규
Issue Date
2010
Publisher
순천향의학연구소
Keywords
Computed tomography; Foreign body; Attenuation coefficient; Hounsfield unit
Citation
Soonchunhyang Medical Science, v.16, no.2, pp 226 - 230
Pages
5
Journal Title
Soonchunhyang Medical Science
Volume
16
Number
2
Start Page
226
End Page
230
URI
https://scholarworks.bwise.kr/sch/handle/2021.sw.sch/18145
ISSN
2233-4289
Abstract
Computed tomography (CT) theoretically improved detection of foreign bodies and provided more information of adjacent soft tissues. The CT scanner and picture archiving and communications system (PACS) program proved to be an excellent instrument for detection and localization of most soft tissue foreign bodies above certain minimum levels of detectability. The characters of metal and non-metal material in penetrating trauma to the soft tissue, it is often underestimated by physical examination. So, diagnosis of a retained foreign object is always critical and difficult. From March 2007 to February 2009 a study was done with 100 patients who had soft tissue trauma. Axial and coronal CT images were obtained with a CT scanner (HiSpeed Advantage CT/i). And then, we measured CT Hounsfield units (HU) of foreign body to remain in the soft tissue. The metallic foreign bodies consisted of stainless steel (2,222±737 HU), titanium (2,921±218 HU), gold (2,908±325 HU), lead (2,758±539 HU), copper (2,909±228 HU), silver (3,069 HU) and mean value is 2,633±603 HU. Non-metallic foreign bodies consisted of silicone (278±120 HU), glass (947±523HU), polyethylene (32±5 HU), polylactide plate (144±16 HU), stone (1,320±280 HU), plastic (-47 HU), wood (-464 HU) and mean value is 557±526 HU. The PACS program allows one to distinguish metallic from nonmetallic foreign bodies and to individually identify the specific composition of many nonmetallic foreign bodies. This program does not, however, allow identification of the specific composition of a metallic foreign body.
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Medicine > Department of Plastic Surgery > 1. Journal Articles
College of Medicine > Department of Plastic Surgery > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Kang, Sang Gue photo

Kang, Sang Gue
College of Medicine (Department of Plastic Surgery)
Read more

Altmetrics

Total Views & Downloads

BROWSE