Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

양성돌발성두위현훈 환자의 임상적 분석

Full metadata record
DC Field Value Language
dc.contributor.author배창희-
dc.contributor.author이인효-
dc.contributor.author김정은-
dc.contributor.author박동욱-
dc.contributor.author장혁순-
dc.contributor.author김동욱-
dc.date.accessioned2021-08-12T07:27:55Z-
dc.date.available2021-08-12T07:27:55Z-
dc.date.created2021-06-17-
dc.date.issued2010-
dc.identifier.issn2092-8882-
dc.identifier.urihttps://scholarworks.bwise.kr/sch/handle/2021.sw.sch/18280-
dc.description.abstractBackground and Objectives: Benign paroxysmal positional vertigo (BPPV) was the most frequent peripheral type vertigo. It has been well controlled with canalith repositioning procedure. Canalith repositioning procedure provides rapid and long-lasting relief of symptoms in most patients with BPPV. However, some patients express nonspecific symptoms such as anxiety or discomfort after canalith repositioning procedure, even after the disappearance of nystagmus and vertigo. The purpose of this study is to assess type distribution of BPPV and relationship between recurrence and subjective residual dizziness after canalith repositioning procedure in patients. Materials and Methods: Ninety-five BPPV patients of 501 patients with dizziness who visited Dizziness Clinic in the Department of Otolaryngology at Soonchunhyang University Hospital from July 2005 to June 2008 were included in this study. These patients were retrospectively reviewed based on clinical charts. In the case of BPPV, repositioning procedure was performed. We analyzed the recurrence, the relationship between recurrence and subjective residual dizziness after canalith repositioning procedure. Results: Overall recurrence rate was 13.6%. Lateral canal origin was more common than posterior canal origin. All cases except 1 were recovered by canalith repositioning procedure. There was no correlation between recurrence and origin, type, subjective residual dizziness of patients. Conclusion: Patients showed various origin, type and recurrence. After the successful canalith repositioning procedure, residual subjective symptoms of patients were presented sometimes, but was no relation to recurrence. Thus, additional follow up and emotional management may be needed.-
dc.language한국어-
dc.language.isoko-
dc.publisher대한평형의학회-
dc.title양성돌발성두위현훈 환자의 임상적 분석-
dc.title.alternativeClinical Study of Benign Paroxysmal Positional Vertigo-
dc.typeArticle-
dc.contributor.affiliatedAuthor김동욱-
dc.identifier.bibliographicCitationResearch in Vestibular Science, v.9, no.3, pp.93 - 99-
dc.relation.isPartOfResearch in Vestibular Science-
dc.citation.titleResearch in Vestibular Science-
dc.citation.volume9-
dc.citation.number3-
dc.citation.startPage93-
dc.citation.endPage99-
dc.type.rimsART-
dc.identifier.kciidART001479186-
dc.description.journalClass2-
dc.description.journalRegisteredClasskci-
dc.description.journalRegisteredClassother-
dc.subject.keywordAuthorBenign paroxysmal positional vertigo-
dc.subject.keywordAuthorRecurrence rate-
dc.subject.keywordAuthor양성돌발성두위현훈-
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Medicine > Department of Otorhinolaryngology > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Altmetrics

Total Views & Downloads

BROWSE