Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

안저골절 정복술 후 풍선 달린 카테터와 방사선 조영제의 이용

Full metadata record
DC Field Value Language
dc.contributor.author최환준-
dc.contributor.author이한정-
dc.contributor.author양형은-
dc.contributor.author이영만-
dc.date.accessioned2021-08-12T07:34:13Z-
dc.date.available2021-08-12T07:34:13Z-
dc.date.issued2010-
dc.identifier.issn2234-6163-
dc.identifier.issn2234-6171-
dc.identifier.urihttps://scholarworks.bwise.kr/sch/handle/2021.sw.sch/18546-
dc.description.abstractPurpose: Blow-out fractures are reduced through transcutaneous or transconjunctival incisions. But the field of orbital surgery is difficult due to lack of visualization of fracture site, blind dissection of orbital floor, susceptibility of injury of orbital structures. In these situations, the former technique of using an antral balloon catheter has advantages over other methods for reconstruction because of its rapidity, simplicity, and inexpensiveness. Furthermore, the antral balloon catheter allows not only elevation of the orbital bone fragment but also expansion of the maxillary sinus in cases where there is a fracture of its walls. But postoperative follow-up method using computed tomography is expensive. Hence, we report a simple and inexpensive follow-up method using radiopaque dye inflation. Methods: We performed endoscopic transantral approach in 5 cases of blow-out fracture under general anesthesia. To accomplish this technique, a rigid 4 mm, 0or 30 degree angled endoscopy was inserted into the maxillary sinus. Inflation of the catheter started gradually,with 10 to 15 mL of saline mixed radiopaque dye (saline:dye, 5 : 1) by syringe and while observing the elevation of the fracture site with endoscope until a proper contour was reached. For the maintain of the position of fractured site,12 French urinary balloon foley catheter were used in fracture site for 7 - 10 days. Results: Postoperative assessment was performed by means of clinical and simple radiographic examination to secure the catheter under the inferior orbital wall and in the maxillary sinus. No specific complications occurred related to this procedure. Results of the surgery and follow-up in all cases were satisfactory. Conclusion: It may be a better alternative to the conventional follow-up method, with less cost and effectiveness of the catheter patency. The advantages of using the urinary balloon foley catheter with the radiopaque dye include the following : it is safe, efficacy, simple, and especially low cost. On drawback of this method is the discomfort to the patient caused by the catheter during the treatment.-
dc.format.extent5-
dc.language한국어-
dc.language.isoKOR-
dc.publisher대한성형외과학회-
dc.title안저골절 정복술 후 풍선 달린 카테터와 방사선 조영제의 이용-
dc.title.alternativeReconstruction of the Orbital Floor Fracture using the Antral Balloon Catheter with Radiopaque Dye-
dc.typeArticle-
dc.publisher.location대한민국-
dc.identifier.bibliographicCitationArchives of Plastic Surgery, v.37, no.1, pp 99 - 103-
dc.citation.titleArchives of Plastic Surgery-
dc.citation.volume37-
dc.citation.number1-
dc.citation.startPage99-
dc.citation.endPage103-
dc.identifier.kciidART001413863-
dc.description.isOpenAccessN-
dc.description.journalRegisteredClasskci-
dc.subject.keywordAuthorBlow-out fracture-
dc.subject.keywordAuthorEndoscope-
dc.subject.keywordAuthorTransantral approach-
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Medicine > Department of Plastic Surgery > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Choi, Hwan jun photo

Choi, Hwan jun
College of Medicine (Department of Plastic Surgery)
Read more

Altmetrics

Total Views & Downloads

BROWSE