수술 중 휴대용 혈색소 광도계를 이용한 혈색소 농도 측정
DC Field | Value | Language |
---|---|---|
dc.contributor.author | 박선영 | - |
dc.contributor.author | 김상현 | - |
dc.contributor.author | 김영록 | - |
dc.contributor.author | 조성환 | - |
dc.contributor.author | 채원석 | - |
dc.contributor.author | 진희철 | - |
dc.contributor.author | 이정석 | - |
dc.contributor.author | 김용익 | - |
dc.date.accessioned | 2021-08-12T07:34:15Z | - |
dc.date.available | 2021-08-12T07:34:15Z | - |
dc.date.issued | 2010 | - |
dc.identifier.issn | 1975-5171 | - |
dc.identifier.issn | 2383-7977 | - |
dc.identifier.uri | https://scholarworks.bwise.kr/sch/handle/2021.sw.sch/18549 | - |
dc.description.abstract | Background: To evaluate the accuracy of a portable hemoglobin photometer, the HemoCue, during surgery, hemoglobin concentrations (Hb) of HemoCue were compared with those of the SYSMEX XE-2100, in the situation of bleeding. Methods: Hemoglobin concentrations were measured with HemoCue and by the SYSMEX XE-2100 at the same time, on 100blood samples obtained from patients who were bleeding more than 500 ml, during surgery. The limits of agreement between the two methods were calculated from the results according to the method of Bland & Altman. The results of HemoCue were adjusted by adding the mean bias, defining the corrected values, and reevaluated the agreement with the results of the SYSMEX XE-2100. Results: The differences in results between the two methods were 1.12 ± 0.37 g/dl. The limits of agreement were 0.38−1.86 g/dl,which means disagreement between the two methods. However,the corrected values represented agreement with the values of the SYSMEX XE-2100. The limits of agreement were −0.74−0.74 g/dl. Conclusions: The corrected Hb values of HemoCue were comparable to the values of SYSMEX XE-2100. It is useful to evaluate the hemoglobin concentration using HemoCue intraoperatively. | - |
dc.format.extent | 5 | - |
dc.language | 한국어 | - |
dc.language.iso | KOR | - |
dc.publisher | 대한마취통증의학회 | - |
dc.title | 수술 중 휴대용 혈색소 광도계를 이용한 혈색소 농도 측정 | - |
dc.title.alternative | Evaluation of a portable hemoglobin photometer for assessment of intra-operative hemoglobin concentrations | - |
dc.type | Article | - |
dc.publisher.location | 대한민국 | - |
dc.identifier.bibliographicCitation | Anesthesia and Pain Medicine, v.5, no.1, pp 87 - 91 | - |
dc.citation.title | Anesthesia and Pain Medicine | - |
dc.citation.volume | 5 | - |
dc.citation.number | 1 | - |
dc.citation.startPage | 87 | - |
dc.citation.endPage | 91 | - |
dc.identifier.kciid | ART001416151 | - |
dc.description.isOpenAccess | N | - |
dc.description.journalRegisteredClass | kciCandi | - |
dc.subject.keywordAuthor | Anemia | - |
dc.subject.keywordAuthor | Hemoglobin | - |
dc.subject.keywordAuthor | Portable hemoglobin photometer. | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
(31538) 22, Soonchunhyang-ro, Asan-si, Chungcheongnam-do, Republic of Korea+82-41-530-1114
COPYRIGHT 2021 by SOONCHUNHYANG UNIVERSITY ALL RIGHTS RESERVED.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.