Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

수술 중 휴대용 혈색소 광도계를 이용한 혈색소 농도 측정

Full metadata record
DC Field Value Language
dc.contributor.author박선영-
dc.contributor.author김상현-
dc.contributor.author김영록-
dc.contributor.author조성환-
dc.contributor.author채원석-
dc.contributor.author진희철-
dc.contributor.author이정석-
dc.contributor.author김용익-
dc.date.accessioned2021-08-12T07:34:15Z-
dc.date.available2021-08-12T07:34:15Z-
dc.date.issued2010-
dc.identifier.issn1975-5171-
dc.identifier.issn2383-7977-
dc.identifier.urihttps://scholarworks.bwise.kr/sch/handle/2021.sw.sch/18549-
dc.description.abstractBackground: To evaluate the accuracy of a portable hemoglobin photometer, the HemoCue, during surgery, hemoglobin concentrations (Hb) of HemoCue were compared with those of the SYSMEX XE-2100, in the situation of bleeding. Methods: Hemoglobin concentrations were measured with HemoCue and by the SYSMEX XE-2100 at the same time, on 100blood samples obtained from patients who were bleeding more than 500 ml, during surgery. The limits of agreement between the two methods were calculated from the results according to the method of Bland & Altman. The results of HemoCue were adjusted by adding the mean bias, defining the corrected values, and reevaluated the agreement with the results of the SYSMEX XE-2100. Results: The differences in results between the two methods were 1.12 ± 0.37 g/dl. The limits of agreement were 0.38−1.86 g/dl,which means disagreement between the two methods. However,the corrected values represented agreement with the values of the SYSMEX XE-2100. The limits of agreement were −0.74−0.74 g/dl. Conclusions: The corrected Hb values of HemoCue were comparable to the values of SYSMEX XE-2100. It is useful to evaluate the hemoglobin concentration using HemoCue intraoperatively.-
dc.format.extent5-
dc.language한국어-
dc.language.isoKOR-
dc.publisher대한마취통증의학회-
dc.title수술 중 휴대용 혈색소 광도계를 이용한 혈색소 농도 측정-
dc.title.alternativeEvaluation of a portable hemoglobin photometer for assessment of intra-operative hemoglobin concentrations-
dc.typeArticle-
dc.publisher.location대한민국-
dc.identifier.bibliographicCitationAnesthesia and Pain Medicine, v.5, no.1, pp 87 - 91-
dc.citation.titleAnesthesia and Pain Medicine-
dc.citation.volume5-
dc.citation.number1-
dc.citation.startPage87-
dc.citation.endPage91-
dc.identifier.kciidART001416151-
dc.description.isOpenAccessN-
dc.description.journalRegisteredClasskciCandi-
dc.subject.keywordAuthorAnemia-
dc.subject.keywordAuthorHemoglobin-
dc.subject.keywordAuthorPortable hemoglobin photometer.-
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Medicine > Department of Anesthesiology > 1. Journal Articles
College of Medicine > Department of Anesthesiology > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Park, Sun Young photo

Park, Sun Young
College of Medicine (Department of Anesthesiology)
Read more

Altmetrics

Total Views & Downloads

BROWSE