Detailed Information

Cited 0 time in webofscience Cited 1 time in scopus
Metadata Downloads

Retrospective multicenter cohort analysis of 621 cases of BellaGel silicone breast implants with study of physicochemical properties and surface topography

Full metadata record
DC Field Value Language
dc.contributor.authorKang, Shin Hyuk-
dc.contributor.authorOh, Joon Seok-
dc.contributor.authorJin, Ung Sik-
dc.contributor.authorBang, Sa Ik-
dc.contributor.authorKim, Ara-
dc.contributor.authorKang, Sang Gue-
dc.contributor.authorKim, Joung Ki-
dc.contributor.authorYoon, Won June-
dc.contributor.authorChang, Jae Hoon-
dc.contributor.authorChoi, Moon Seop-
dc.contributor.authorSeul, Chul Hwan-
dc.contributor.authorHeo, Chan Yeong-
dc.date.accessioned2021-09-10T06:24:12Z-
dc.date.available2021-09-10T06:24:12Z-
dc.date.issued2021-03-
dc.identifier.issn1748-6815-
dc.identifier.issn1878-0539-
dc.identifier.urihttps://scholarworks.bwise.kr/sch/handle/2021.sw.sch/18976-
dc.description.abstractThis study aimed to assess the effectiveness and safety of BellaGel implants after implantation in Asian women and inform surgeons of another option for use in breast augmentation and reconstruction. This study was conducted in eight hospitals from November 27, 2015 to April 30, 2018. All patients underwent augmentation mammoplasty or implant-based breast reconstruction with BellaGel implants. Complication rates were compared between groups, and the cumulative hazard function was compared using the Kaplan-Meier survival analysis. Implants were grouped by surface type, and the cumulative hazard functions of total complication cases were compared. The biomechanical properties of the BellaGel implant and other company representative implants were tested using a mechanical testing machine, and surface topography was analyzed using a 3D laser scanning confocal microscope. There was a significant difference in the incidence of complications between the reconstruction (17.1%) and augmentation (4.7%) groups, but no significant difference in the complication rates of each group. There was no difference in the reoperation or revision rates between the groups. The log rank test showed a statistically significant difference in cumulative hazard function between the groups. Among the three types of implants (smooth, textured, and microtextured), the microtextured type had the lowest complication rate. The BellaGel microtexture implant had the highest maximal tensile load and displacement value. The BellaGel and Silksurface implants had the highest stored energy, although there was no significant difference. BellaGel implants can serve as a criterion for the selection of safe and effective implants among currently available implants. (C) 2020 British Association of Plastic, Reconstructive and Aesthetic Surgeons. Published by Elsevier Ltd. All rights reserved.-
dc.format.extent9-
dc.language영어-
dc.language.isoENG-
dc.publisherElsevier BV-
dc.titleRetrospective multicenter cohort analysis of 621 cases of BellaGel silicone breast implants with study of physicochemical properties and surface topography-
dc.typeArticle-
dc.publisher.location영국-
dc.identifier.doi10.1016/j.bjps.2020.08.134-
dc.identifier.scopusid2-s2.0-85092940995-
dc.identifier.wosid000622322500005-
dc.identifier.bibliographicCitationJournal of Plastic, Reconstructive and Aesthetic Surgery, v.74, no.3, pp 486 - 494-
dc.citation.titleJournal of Plastic, Reconstructive and Aesthetic Surgery-
dc.citation.volume74-
dc.citation.number3-
dc.citation.startPage486-
dc.citation.endPage494-
dc.type.docTypeArticle-
dc.description.isOpenAccessN-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
dc.relation.journalResearchAreaSurgery-
dc.relation.journalWebOfScienceCategorySurgery-
dc.subject.keywordAuthorBreast implant-
dc.subject.keywordAuthorBellaGel-
dc.subject.keywordAuthorPhysicochemical property-
dc.subject.keywordAuthorRetrospective study-
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Medicine > Department of Plastic Surgery > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Kang, Sang Gue photo

Kang, Sang Gue
College of Medicine (Department of Plastic Surgery)
Read more