Detailed Information

Cited 0 time in webofscience Cited 2 time in scopus
Metadata Downloads

Diagnostic Accuracy of CT-Guided Core Needle Biopsy for Thin-Walled Cavitary Pulmonary Lesions

Full metadata record
DC Field Value Language
dc.contributor.authorShin, Kyung Eun-
dc.contributor.authorPark, Jai Soung-
dc.contributor.authorLee, Jae Wook-
dc.date.accessioned2021-09-10T06:24:37Z-
dc.date.available2021-09-10T06:24:37Z-
dc.date.issued2021-02-
dc.identifier.issn0361-803X-
dc.identifier.issn1546-3141-
dc.identifier.urihttps://scholarworks.bwise.kr/sch/handle/2021.sw.sch/18992-
dc.description.abstractOBJECTIVE. The purpose of this article is to evaluate the accuracy of and complications with CT-guided percutaneous core needle biopsy (CNB) of thin-walled cavitary pulmonary lesions. MATERIALS AND METHODS. This retrospective study involved 32 CNBs in 30 patients who had thin-walled cavitary pulmonary lesions (wall thickness < 5 mm) and underwent CT-guided CNB. After the 30 patient records were evaluated for the diagnostic accuracy, sensitivity, and specificity of CT-guided CNB, the results were compared with the final diagnosis after surgery or clinical follow-up. Each patient was reviewed for complications including pneumothorax, thoracotomy tube insertion, hemorrhage, and hemoptysis. RESULTS. The final diagnosis indicated 19 malignant and 11 benign lesions. Two lesions with indeterminate biopsy results (anthracofibrosis and focal interstitial thickening) were excluded. The sensitivity, specificity, and diagnostic accuracy of thin-walled cavities were 89.5%, 100%, and 93.3%, respectively. There were no statistical differences in the accuracy, sensitivity, or specificity according to wall thickness, cavity size, or lesion depth. Chest CT immediately after biopsy revealed mild pneumothorax in seven patients and moderate to severe pneumothorax requiring placement of a thoracotomy tube in one patient. CT after biopsy indicated mild parenchymal hemorrhage in 15 patients and hemoptysis in one patient. CONCLUSION. CT-guided CNB is a useful and accurate diagnostic technique for biopsy of a pulmonary thin-walled cavity.-
dc.format.extent7-
dc.language영어-
dc.language.isoENG-
dc.publisherAmerican Roentgen Ray Society-
dc.titleDiagnostic Accuracy of CT-Guided Core Needle Biopsy for Thin-Walled Cavitary Pulmonary Lesions-
dc.typeArticle-
dc.publisher.location미국-
dc.identifier.doi10.2214/AJR.20.22780-
dc.identifier.scopusid2-s2.0-85100280477-
dc.identifier.wosid000642944000016-
dc.identifier.bibliographicCitationAmerican Journal of Roentgenology, v.216, no.2, pp 369 - 375-
dc.citation.titleAmerican Journal of Roentgenology-
dc.citation.volume216-
dc.citation.number2-
dc.citation.startPage369-
dc.citation.endPage375-
dc.type.docTypeArticle-
dc.description.isOpenAccessN-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
dc.relation.journalResearchAreaRadiology, Nuclear Medicine & Medical Imaging-
dc.relation.journalWebOfScienceCategoryRadiology, Nuclear Medicine & Medical Imaging-
dc.subject.keywordPlusASPIRATION BIOPSY-
dc.subject.keywordPlusRISK-FACTORS-
dc.subject.keywordPlusLUNG-BIOPSY-
dc.subject.keywordPlus20 MM-
dc.subject.keywordPlusCAVITIES-
dc.subject.keywordPlusFEATURES-
dc.subject.keywordAuthorcomplication rate-
dc.subject.keywordAuthorCT-guided core needle biopsy-
dc.subject.keywordAuthordiagnostic accuracy-
dc.subject.keywordAuthorthin-walled pulmonary cavity-
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Medicine > Department of Radiology > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Lee, Jae Wook photo

Lee, Jae Wook
College of Medicine (Department of Radiology)
Read more

Altmetrics

Total Views & Downloads

BROWSE