Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

A Comparison of Central Corneal Thickness Measurements and Measurement Repeatability Using Three Imaging Modalities

Full metadata record
DC Field Value Language
dc.contributor.authorWoo, Sang Earn-
dc.contributor.authorLee, Si Hyung-
dc.date.accessioned2021-09-10T06:24:43Z-
dc.date.available2021-09-10T06:24:43Z-
dc.date.issued2021-02-
dc.identifier.issn0378-6471-
dc.identifier.issn2092-9374-
dc.identifier.urihttps://scholarworks.bwise.kr/sch/handle/2021.sw.sch/18996-
dc.description.abstractPurpose: To compare and analyze central corneal thickness (CCT) measurements and measurement repeatability according to the corneal thickness obtained with anterior segment optical coherence tomography (AS-OCT), ultrasound pachymetry (USP), and dual Scheimpflug imaging (Galilei G4 (R)). Methods: CCT measurements obtained using AS-OCT, USP, and a dual rotating Scheimpflug camera in 120 eyes of 60 healthy subjects were compared and the repeatability was analyzed. Results: The average CCT measurements using AS-OCT, USP, and a dual rotating Scheimpflug camera were 511.23 +/- 37.16, 525.78 +/- 39.22, and 531.43 +/- 41.57 mu m, respectively. The CCT measurement using dual rotating Scheimpflug imaging was statistically significantly thicker than that measured using AS-OCT (p < 0.05). A significant linear correlation was observed among OCT, USP, and dual rotating Scheimpflug measurements (r > 0.900, p < 0.001). All three methods showed high repeatability (intraclass correlation coefficient >= 0.996) for intra-examiner CCT measurements. Conclusions: The CCT measurement results using the three methods were significantly correlated and showed high repeatability. However, the AS-OCT measurement was significantly thinner than that obtained using a dual rotating Scheimpflug camera. CCT measurement with a dual rotating Scheimpflug camera is a better alternative for USP than AS-OCT. Therefore, CCT should be interpreted in the context of the instrument used.-
dc.format.extent9-
dc.language한국어-
dc.language.isoKOR-
dc.publisher대한안과학회-
dc.titleA Comparison of Central Corneal Thickness Measurements and Measurement Repeatability Using Three Imaging Modalities-
dc.title.alternative세 가지 기기를 이용하여 측정한 중심각막두께의 비교 및 반복성 비교-
dc.typeArticle-
dc.publisher.location대한민국-
dc.identifier.doi10.3341/jkos.2021.62.2.184-
dc.identifier.scopusid2-s2.0-85101737360-
dc.identifier.wosid000620709300005-
dc.identifier.bibliographicCitation대한안과학회지, v.62, no.2, pp 184 - 192-
dc.citation.title대한안과학회지-
dc.citation.volume62-
dc.citation.number2-
dc.citation.startPage184-
dc.citation.endPage192-
dc.type.docTypeArticle-
dc.identifier.kciidART002683503-
dc.description.isOpenAccessN-
dc.description.journalRegisteredClassscopus-
dc.description.journalRegisteredClassesci-
dc.description.journalRegisteredClasskci-
dc.relation.journalResearchAreaOphthalmology-
dc.relation.journalWebOfScienceCategoryOphthalmology-
dc.subject.keywordPlusOPTICAL COHERENCE TOMOGRAPHY-
dc.subject.keywordPlusDUAL SCHEIMPFLUG ANALYZER-
dc.subject.keywordPlusIN-SITU KERATOMILEUSIS-
dc.subject.keywordPlusULTRASOUND PACHYMETRY-
dc.subject.keywordPlusGLAUCOMA-
dc.subject.keywordPlusREPRODUCIBILITY-
dc.subject.keywordPlusAGREEMENT-
dc.subject.keywordPlusDEVICES-
dc.subject.keywordPlusSURGERY-
dc.subject.keywordPlusORBSCAN-
dc.subject.keywordAuthorAnterior segment optical coherence tomography-
dc.subject.keywordAuthorCentral corneal thickness-
dc.subject.keywordAuthorDual rotating Scheimpflug camera-
dc.subject.keywordAuthorUltrasound pachymetry-
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Medicine > Department of Ophthalmology > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Lee, Si Hyung photo

Lee, Si Hyung
College of Medicine (Department of Ophthalmology)
Read more

Altmetrics

Total Views & Downloads

BROWSE