Detailed Information

Cited 0 time in webofscience Cited 2 time in scopus
Metadata Downloads

Micro- and nano-tomography analysis of mouse soleus muscle using radiation

Full metadata record
DC Field Value Language
dc.contributor.authorJang, Sang-Hun-
dc.contributor.authorLee, Jiwon-
dc.contributor.authorLee, Onseok-
dc.date.accessioned2021-09-10T06:44:59Z-
dc.date.available2021-09-10T06:44:59Z-
dc.date.issued2021-11-
dc.identifier.issn1059-910X-
dc.identifier.issn1097-0029-
dc.identifier.urihttps://scholarworks.bwise.kr/sch/handle/2021.sw.sch/19315-
dc.description.abstractIn this study, we analyze radiation images of muscle structure of mice soleus muscles using radiation source-based microtomography and nanotomography. Soleus muscle samples were collected for analysis from 8-week-old male Institute of Cancer Research mice. First, phase-contrast X-ray microtomography was employed in these experiments. Then to obtain images with excellent contrast, imaging was performed using monochromatic light with excellent transmission power. To analyze additional muscle structures in higher magnification images than these images, nanotomography was performed, which facilitated obtaining high-magnification and high-resolution images. Muscle tissue microstructures were confirmed through three-dimensional images obtained from phase-contrast X-ray microtomography. Thus, the muscle tissue's overall shape at microscopic level can be captured. Additionally, a single muscle fiber was examined using hard X-ray nano-imaging, through which we could observe the alignment of countless myofibrils, that is, actin and myosin filaments in the muscle fibers. Thus, the methodology adopted here proved to be advantageous in analyzing the muscle tissue's overall structure with microtomography and in observing the myofibrils in detail using nanotomography.-
dc.format.extent9-
dc.language영어-
dc.language.isoENG-
dc.publisherJohn Wiley & Sons Inc.-
dc.titleMicro- and nano-tomography analysis of mouse soleus muscle using radiation-
dc.typeArticle-
dc.publisher.location미국-
dc.identifier.doi10.1002/jemt.23819-
dc.identifier.scopusid2-s2.0-85106225021-
dc.identifier.wosid000652759500001-
dc.identifier.bibliographicCitationMicroscopy Research and Technique, v.84, no.11, pp 2685 - 2693-
dc.citation.titleMicroscopy Research and Technique-
dc.citation.volume84-
dc.citation.number11-
dc.citation.startPage2685-
dc.citation.endPage2693-
dc.type.docTypeArticle-
dc.description.isOpenAccessN-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
dc.relation.journalResearchAreaAnatomy & Morphology-
dc.relation.journalResearchAreaLife Sciences & Biomedicine - Other Topics-
dc.relation.journalResearchAreaMicroscopy-
dc.relation.journalWebOfScienceCategoryAnatomy & Morphology-
dc.relation.journalWebOfScienceCategoryBiology-
dc.relation.journalWebOfScienceCategoryMicroscopy-
dc.subject.keywordPlusX-RAY MICROTOMOGRAPHY-
dc.subject.keywordPlusSKELETAL-MUSCLE-
dc.subject.keywordPlusSYNCHROTRON-RADIATION-
dc.subject.keywordPlusCOMPUTED-TOMOGRAPHY-
dc.subject.keywordPlusSCIATIC-NERVE-
dc.subject.keywordPlusTISSUE-
dc.subject.keywordPlusTRANSECTION-
dc.subject.keywordPlusADULT-
dc.subject.keywordPlusMRI-
dc.subject.keywordAuthoractin-
dc.subject.keywordAuthormyofibril-
dc.subject.keywordAuthormyosin-
dc.subject.keywordAuthorX&#8208-
dc.subject.keywordAuthorray microtomography-
dc.subject.keywordAuthorX&#8208-
dc.subject.keywordAuthorray nanotomography-
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Medical Sciences > Department of Medical IT Engineering > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Lee, On Seok photo

Lee, On Seok
College of Software Convergence (의료IT공학과)
Read more

Altmetrics

Total Views & Downloads

BROWSE