Evaluation of error inducing factors in unmanned aerial vehicle mounted detector to measure fugitive methane from solid waste landfill
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Kim, Yeong Min | - |
dc.contributor.author | Park, Man Ho | - |
dc.contributor.author | Jeong, Sangjae | - |
dc.contributor.author | Lee, Kyeong Ho | - |
dc.contributor.author | Kim, Jae Young | - |
dc.date.accessioned | 2021-08-11T08:26:50Z | - |
dc.date.available | 2021-08-11T08:26:50Z | - |
dc.date.issued | 2021-04-01 | - |
dc.identifier.issn | 0956-053X | - |
dc.identifier.issn | 1879-2456 | - |
dc.identifier.uri | https://scholarworks.bwise.kr/sch/handle/2021.sw.sch/1960 | - |
dc.description.abstract | Many methods have been applied to monitor fugitive methane gas from landfills. Recently, there have been suggestions to use a framework utilizing an unmanned aerial vehicle (UAV) for landfill gas monitoring, and several field campaigns have proved that a rotary UAV-based measurement has advantages of ease of control and high-resolution concentration mapping on the target planes. However, research on the evaluation of error-inducing factors in the suggested system is limited so far. This study prepared a measurement system with a lightweight methane detector and a rotary UAV to support the applicability of rotary UAV in landfill gas monitoring. Then, the validity of the system was tested experimentally and theoretically. In the detector reliability test, the methane detector had sufficient resolution for field application. The critical UAV velocity required was obtained to ensure the credibility of the proposed measurement system. When spatial interpolators were applied to field data from the measurement system, the empirical Bayesian kriging demonstrated the best prediction of methane concentrations at unmeasured points. With the verifications provided in this study, this proposed method may contribute to reducing uncertainty in estimating fugitive landfill gas emission. (c) 2021 Elsevier Ltd. All rights reserved. | - |
dc.format.extent | 9 | - |
dc.language | 영어 | - |
dc.language.iso | ENG | - |
dc.publisher | Pergamon Press Ltd. | - |
dc.title | Evaluation of error inducing factors in unmanned aerial vehicle mounted detector to measure fugitive methane from solid waste landfill | - |
dc.type | Article | - |
dc.publisher.location | 영국 | - |
dc.identifier.doi | 10.1016/j.wasman.2021.02.023 | - |
dc.identifier.scopusid | 2-s2.0-85101850749 | - |
dc.identifier.wosid | 000631975400009 | - |
dc.identifier.bibliographicCitation | Waste Management, v.124, pp 368 - 376 | - |
dc.citation.title | Waste Management | - |
dc.citation.volume | 124 | - |
dc.citation.startPage | 368 | - |
dc.citation.endPage | 376 | - |
dc.type.docType | Article | - |
dc.description.isOpenAccess | N | - |
dc.description.journalRegisteredClass | scie | - |
dc.description.journalRegisteredClass | scopus | - |
dc.relation.journalResearchArea | Engineering | - |
dc.relation.journalResearchArea | Environmental Sciences & Ecology | - |
dc.relation.journalWebOfScienceCategory | Engineering, Environmental | - |
dc.relation.journalWebOfScienceCategory | Environmental Sciences | - |
dc.subject.keywordPlus | QUANTIFICATION | - |
dc.subject.keywordPlus | EMISSIONS | - |
dc.subject.keywordPlus | FLUX | - |
dc.subject.keywordPlus | GAS | - |
dc.subject.keywordAuthor | Emission monitoring | - |
dc.subject.keywordAuthor | Greenhouse gas | - |
dc.subject.keywordAuthor | Landfill gas | - |
dc.subject.keywordAuthor | Methane | - |
dc.subject.keywordAuthor | Unmanned aerial vehicle | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
(31538) 22, Soonchunhyang-ro, Asan-si, Chungcheongnam-do, Republic of Korea+82-41-530-1114
COPYRIGHT 2021 by SOONCHUNHYANG UNIVERSITY ALL RIGHTS RESERVED.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.