Longbone 검출기를 이용한 Scanogram의 유효성 평가Effectiveness Evaluation of Scanogram Using Longbone Detector

Other Titles
Effectiveness Evaluation of Scanogram Using Longbone Detector
Authors
장수한허지은
Issue Date
2020
Publisher
대한방사선과학회
Keywords
Scanogram; Lone bone detector; Scolosis; Whole spine scanogram; Lower leg scanogram; Single expourse method; Tube ratation method; 장골계측; 장골검출기; 척추측만증; 전척추 검사; 전하지 검사; 단일 조사방식; 튜브 회전방식
Citation
방사선기술과학, v.43, no.4, pp.235 - 242
Journal Title
방사선기술과학
Volume
43
Number
4
Start Page
235
End Page
242
URI
https://scholarworks.bwise.kr/sch/handle/2021.sw.sch/19624
ISSN
2288-3509
Abstract
Scanogram is that combine several practical images into one image to observation. So it is an important consideration in many clinical situation such as iliac measurement, leg alignment measurement and Scoliosis. Currently, scanogram examinations are mainly conducted for children and elderly patients. In this study, in order to apply the longbone detector to children or elderly patients who are difficult to cooperate with, we compared the longbone detector from D equipment with the G equipment discovery 656 Puls equipment in reproducibility of images, distribution of irradiation dose, scattering dose, irradiation time and image acquisition time. D equipment took more than twice as much time as G equipment. The scattered dose generated about 50% more G equipment than D equipment. In the whole spine scanogram and the measurement length of the lower leg, D equipment was also measured longer than G equipment. However, both methods did not show much difference from the CT scanogram, so there was no problem in measurement. The height of the thyroid radiation dose of G equipment was produced more radiation than D equipment. However, the longbone detector deviated from the x-ray center line relative to the tube rotation method, and was measured lower by the directionality of the measuring instrument, so that the error could not be corrected. In the conclusion of study, using the longbone detector is excellent for applying to children or elderly patients to reduce scattering dose. However, using CR may be useful to normal patients. Because, the image quality may deteriorate due to an imbalance of dose difference in thickness depending on the body part. So, it is useful to using a compensation filter or tube rotation method when we take a whole spine scanogram.
Files in This Item
There are no files associated with this item.
Appears in
Collections
ETC > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Altmetrics

Total Views & Downloads

BROWSE