혈액응고장비 CS-5100의 특수혈액응고 항목 성능 평가
DC Field | Value | Language |
---|---|---|
dc.contributor.author | 김보현 | - |
dc.contributor.author | 장성수 | - |
dc.contributor.author | 이유진 | - |
dc.contributor.author | 박누리 | - |
dc.contributor.author | 조영욱 | - |
dc.contributor.author | 박찬정 | - |
dc.date.accessioned | 2021-09-10T07:25:35Z | - |
dc.date.available | 2021-09-10T07:25:35Z | - |
dc.date.created | 2021-06-17 | - |
dc.date.issued | 2020 | - |
dc.identifier.issn | 2093-6338 | - |
dc.identifier.uri | https://scholarworks.bwise.kr/sch/handle/2021.sw.sch/19633 | - |
dc.description.abstract | Background: The CS-5100 high-throughput automated coagulometer (Sysmex, Japan) can perform general and special coagulation assays. We evaluated the performance of the CS-5100 coagulometer to measure fibrinogen degradation product (FDP), plasma level of unfractionated heparin (UFH), low molecular weight heparin (LMWH), and direct oral anticoagulants (DOACs). Methods: Precision, linearity, and carryover rate of the CS-5100 while measuring FDP, UFH, and LMWH were validated. Precision and linearity were validated for measurements of DOACs. Results of FDP measurement using CS-5100 were compared to those using the currently used STA-R coagulometer (Diagnostica Stago, France). The reference range of FDP was established. All evaluation procedures were in accordance with Clinical and Laboratory Standards Institute guidelines. Results: CS-5100 displayed good precision, linearity, and carryover rate for measuring FDP, UFH, LMWH, and DOACs. The FDP level measured with the CS-5100 and STA-R coagulometers correlated well. The reference range of FDP with CS-5100 was 0.0 to 3.48 µg/mL. Conclusions: The CS-5100 coagulometer has acceptable analytical performance in measuring special coagulation parameters. It is suitable for the reliable measurement of plasma FDP and anticoagulant levels in clinical laboratories. | - |
dc.language | 영어 | - |
dc.language.iso | en | - |
dc.publisher | 대한진단검사의학회 | - |
dc.title | 혈액응고장비 CS-5100의 특수혈액응고 항목 성능 평가 | - |
dc.title.alternative | Performance Evaluation of the CS-5100 Coagulation Analyzer for Special Coagulation Parameters | - |
dc.type | Article | - |
dc.contributor.affiliatedAuthor | 김보현 | - |
dc.identifier.bibliographicCitation | Laboratory Medicine Online, v.10, no.1, pp.25 - 32 | - |
dc.relation.isPartOf | Laboratory Medicine Online | - |
dc.citation.title | Laboratory Medicine Online | - |
dc.citation.volume | 10 | - |
dc.citation.number | 1 | - |
dc.citation.startPage | 25 | - |
dc.citation.endPage | 32 | - |
dc.type.rims | ART | - |
dc.identifier.kciid | ART002545927 | - |
dc.description.journalClass | 2 | - |
dc.description.journalRegisteredClass | kci | - |
dc.subject.keywordAuthor | CS-5100 | - |
dc.subject.keywordAuthor | FDP | - |
dc.subject.keywordAuthor | Anticoagulants | - |
dc.subject.keywordAuthor | Heparin | - |
dc.subject.keywordAuthor | Low molecular weight heparin | - |
dc.subject.keywordAuthor | Direct oral anticoagulant | - |
dc.subject.keywordAuthor | Performance | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
(31538) 22, Soonchunhyang-ro, Asan-si, Chungcheongnam-do, Republic of Korea+82-41-530-1114
COPYRIGHT 2021 by SOONCHUNHYANG UNIVERSITY ALL RIGHTS RESERVED.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.