Spinal nerve signal intensity on Dixon T2-weighted water-only sequence: an important outcome predictor after lumbar transforaminal epidural injection
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Kim, Yong Hee | - |
dc.contributor.author | Kim, Hyo Jin | - |
dc.contributor.author | Seo, Jiwoon | - |
dc.contributor.author | Chai, Jee Won | - |
dc.contributor.author | Song, Hyun-Gul | - |
dc.contributor.author | Choi, Yoon-Hee | - |
dc.contributor.author | Kim, Dong Hyun | - |
dc.date.accessioned | 2022-01-25T01:40:30Z | - |
dc.date.available | 2022-01-25T01:40:30Z | - |
dc.date.issued | 2021-12 | - |
dc.identifier.issn | 0938-7994 | - |
dc.identifier.issn | 1432-1084 | - |
dc.identifier.uri | https://scholarworks.bwise.kr/sch/handle/2021.sw.sch/20269 | - |
dc.description.abstract | Objectives To evaluate the role of Dixon T2-weighted water-fat separation technique in predicting the outcome of lumbar transforaminal epidural injections (TFESIs). Methods Patients who underwent TFESI of a single spinal nerve within 3 months after magnetic resonance imaging (MRI) exam between August 2018 and April 2020 were identified. The patients were classified into positive or negative outcome groups based on the response to the TFESI procedure. Two musculoskeletal radiologists measured the signal intensity of the injected side spinal nerves, contralateral side spinal nerves, and subcutaneous fat on axial Dixon T2-weighted water-only images, and the diameter of spinal nerve on axial Dixon T2-weighted in-phase images of the pre-procedural MRI. The measured values of the injected side spinal nerves were compared between the two groups and with the contralateral side spinal nerve. Results A total of 94 patients were included, 76 in the positive outcome group and 18 in the negative outcome group. The mean signal intensity and the nerve-to-fat signal ratio of the injected side spinal nerve were significantly higher in the positive outcome group than in the negative outcome group (793.78 vs. 679.19, p = 0.016; 4.21 vs. 3.28, p = 0.003). In the positive outcome group, the diameter of the spinal nerve was significantly higher on the injected side than on the contralateral side (6.91 mm vs. 6.37 mm, p = 0.016). Conclusions The mean signal intensity and the nerve-to-fat signal ratio of the spinal nerve on axial Dixon T2-weighted water-only images can help predict patient response to the TFESI. | - |
dc.format.extent | 9 | - |
dc.language | 영어 | - |
dc.language.iso | ENG | - |
dc.publisher | Springer Verlag | - |
dc.title | Spinal nerve signal intensity on Dixon T2-weighted water-only sequence: an important outcome predictor after lumbar transforaminal epidural injection | - |
dc.type | Article | - |
dc.publisher.location | 미국 | - |
dc.identifier.doi | 10.1007/s00330-021-08119-x | - |
dc.identifier.scopusid | 2-s2.0-85108159513 | - |
dc.identifier.wosid | 000662123900003 | - |
dc.identifier.bibliographicCitation | European Radiology, v.31, no.12, pp 9459 - 9467 | - |
dc.citation.title | European Radiology | - |
dc.citation.volume | 31 | - |
dc.citation.number | 12 | - |
dc.citation.startPage | 9459 | - |
dc.citation.endPage | 9467 | - |
dc.type.docType | Article | - |
dc.description.isOpenAccess | N | - |
dc.description.journalRegisteredClass | scie | - |
dc.description.journalRegisteredClass | scopus | - |
dc.relation.journalResearchArea | Radiology, Nuclear Medicine & Medical Imaging | - |
dc.relation.journalWebOfScienceCategory | Radiology, Nuclear Medicine & Medical Imaging | - |
dc.subject.keywordPlus | STEROID INJECTION | - |
dc.subject.keywordPlus | FAT-SUPPRESSION | - |
dc.subject.keywordPlus | RADICULAR PAIN | - |
dc.subject.keywordPlus | MRI-FINDINGS | - |
dc.subject.keywordPlus | STENOSIS | - |
dc.subject.keywordAuthor | Magnetic resonance imaging | - |
dc.subject.keywordAuthor | Spinal nerves | - |
dc.subject.keywordAuthor | Radiculopathy | - |
dc.subject.keywordAuthor | Injections | - |
dc.subject.keywordAuthor | Steroids | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
(31538) 22, Soonchunhyang-ro, Asan-si, Chungcheongnam-do, Republic of Korea+82-41-530-1114
COPYRIGHT 2021 by SOONCHUNHYANG UNIVERSITY ALL RIGHTS RESERVED.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.