Two-megahertz impedance index prediction equation for appendicular lean mass in Korean older people
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Kim, Hyeoijin | - |
dc.contributor.author | Song, Keon-Hyoung | - |
dc.contributor.author | Ambegaonkar, Jatin P. | - |
dc.contributor.author | Chung, Sochung | - |
dc.contributor.author | Jeon, Kwonchan | - |
dc.contributor.author | Jiang, Fang Lin | - |
dc.contributor.author | Eom, Jin Jong | - |
dc.contributor.author | Kim, Chul-Hyun | - |
dc.date.accessioned | 2022-05-12T00:47:37Z | - |
dc.date.available | 2022-05-12T00:47:37Z | - |
dc.date.issued | 2022-05 | - |
dc.identifier.issn | 1471-2318 | - |
dc.identifier.uri | https://scholarworks.bwise.kr/sch/handle/2021.sw.sch/20739 | - |
dc.description.abstract | Background: Whole-body bioelectrical impedance analysis (BIA) has been accepted as an indirect method to estimate appendicular lean mass (ALM) comparable to dual-energy X-ray absorptiometry (DXA). However, single or limited frequencies currently used for these estimates may over or under-estimate ALM. Accordingly, there is a need to measure the impedance parameter with appendicular lean-specific across multiple frequencies to more accurately estimate ALM. We aimed to validate muscle-specific frequency BIA equation for ALM using multifrequency BIA (MF-BIA) with DXA as the reference. Methods: 195 community-dwelling Korean older people (94 men and 101 women) aged 70 similar to 92y participated in this study. ALM was measured by DXA and bioimpedance measures at frequencies of 5 kHz similar to 3 MHz were assessed for independent predictive variables. Regression analyses were used to find limb-specific frequencies of bioimpedance, to develop the ALM equations and to conduct the internal cross-validation. The six published equations and the final equation of MF-BIA were externally cross-validated. Results: 195 participants completed the measurements of MF-BIA and DXA. Using bivariate regression analysis, the 2 MHz impedance index explained R-2 = 91.5% of variability (P < 0.001) in ALM and predictive accuracy of standard error of estimate (SEE) was 1.0822 kg ALM (P < 0.001). Multiple stepwise regression analysis obtained in the development group had an adjusted R-2 of 9.28% (P < 0.001) and a SEE of 0.97 kg ALM. The cross-validation group had no significant difference between the measured ALM and the predicted ALM (17.8 +/- 3.9 kg vs. 17.7 +/- 3.8 kg, P = .486) with 93.1% of R-2 (P < 0.001) and 1.00 kg ALM of total error. The final regression equation was as follows: ALM = 0.247ZI(@2 MHz) + 1.254SEX(M1F0) + 0.067Xc(@5 kHz) + 1.739 with 93% of R2 (P < 0.001), 0.97 kg ALM of SEE (Subjective Rating as "excellent" for men and "very good" for women). In the analysis of the diagnostic level for sarcopenia of the final regression, the overall agreement was 94.9% (k = 0.779, P < 0.001) with 71.4% of sensitivity, 98.8% of specificity, 91.3 of positive prediction value and 95.3% of negative prediction value. Conclusion: The newly developed appendicular lean-specific high-frequency BIA prediction equation has a high predictive accuracy, sensitivity, specificity, and agreement for both individual and group measurements. Thus, the high-frequency BIA prediction equation is suitable not only for epidemiological studies, but also for the diagnosis of sarcopenia in clinical settings. | - |
dc.format.extent | 11 | - |
dc.language | 영어 | - |
dc.language.iso | ENG | - |
dc.publisher | BioMed Central | - |
dc.title | Two-megahertz impedance index prediction equation for appendicular lean mass in Korean older people | - |
dc.type | Article | - |
dc.publisher.location | 영국 | - |
dc.identifier.doi | 10.1186/s12877-022-02997-6 | - |
dc.identifier.scopusid | 2-s2.0-85129283229 | - |
dc.identifier.wosid | 000789808800006 | - |
dc.identifier.bibliographicCitation | BMC Geriatrics, v.22, no.1, pp 1 - 11 | - |
dc.citation.title | BMC Geriatrics | - |
dc.citation.volume | 22 | - |
dc.citation.number | 1 | - |
dc.citation.startPage | 1 | - |
dc.citation.endPage | 11 | - |
dc.type.docType | Article | - |
dc.description.isOpenAccess | Y | - |
dc.description.journalRegisteredClass | scie | - |
dc.description.journalRegisteredClass | ssci | - |
dc.description.journalRegisteredClass | scopus | - |
dc.relation.journalResearchArea | Geriatrics & Gerontology | - |
dc.relation.journalWebOfScienceCategory | Geriatrics & Gerontology | - |
dc.relation.journalWebOfScienceCategory | Gerontology | - |
dc.subject.keywordPlus | SKELETAL-MUSCLE MASS | - |
dc.subject.keywordPlus | TOTAL-BODY WATER | - |
dc.subject.keywordPlus | BIOELECTRICAL-IMPEDANCE | - |
dc.subject.keywordPlus | EXTRACELLULAR WATER | - |
dc.subject.keywordPlus | WHOLE-BODY | - |
dc.subject.keywordPlus | SARCOPENIA | - |
dc.subject.keywordPlus | VALIDATION | - |
dc.subject.keywordPlus | CONSENSUS | - |
dc.subject.keywordPlus | ACCURACY | - |
dc.subject.keywordPlus | QUALITY | - |
dc.subject.keywordAuthor | Appendicular skeletal muscle mass | - |
dc.subject.keywordAuthor | Diagnosis | - |
dc.subject.keywordAuthor | Multifrequency Bioelectrical Impedance Analysis | - |
dc.subject.keywordAuthor | Validation | - |
dc.subject.keywordAuthor | Algorithm | - |
dc.subject.keywordAuthor | Dual-energy X-ray Absorptiometry | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
(31538) 22, Soonchunhyang-ro, Asan-si, Chungcheongnam-do, Republic of Korea+82-41-530-1114
COPYRIGHT 2021 by SOONCHUNHYANG UNIVERSITY ALL RIGHTS RESERVED.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.