Robust skin microrelief depth estimation using a mobile stereo system
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Moon, Cho-, I | - |
dc.contributor.author | Lee, Onseok | - |
dc.contributor.author | Choi, Min-Hyung | - |
dc.date.accessioned | 2022-11-29T05:41:07Z | - |
dc.date.available | 2022-11-29T05:41:07Z | - |
dc.date.issued | 2022-11 | - |
dc.identifier.issn | 0909-752X | - |
dc.identifier.issn | 1600-0846 | - |
dc.identifier.uri | https://scholarworks.bwise.kr/sch/handle/2021.sw.sch/21763 | - |
dc.description.abstract | Background The skin surface becomes wrinkled and rough due to various internal and external factors. A three-dimensional (3D) analysis of the skin is required to improve skin conditions. Stereophotogrammetry, a noninvasive 3D analysis method, is easy to install and use, but most stereo systems have a fixed baseline and scale. Previous stereo systems are not suitable for observing micro-range skin features. Therefore, we suggest the optimal conditions and methods for the 3D analysis of skin microrelief using a multi-conditioned stereo system. Methods We constructed a nonconvergence model using a mobile device and acquired stereo images under multiscale and multi-baseline conditions. We extracted 3D information of the skin through our process: preprocessing, skin feature extraction, feature matching, and actual depth mapping. We improved the accuracy of the 3D analysis of the skin by using disparity values instead of disparity maps. We compared and analyzed the performances of six local feature detector and descriptor algorithms. In addition, we suggested depth-mapping formulas to estimate the actual depth of the skin microrelief. Results We confirmed that stereo images with a working distance of 70-75 mm and a baseline of 4-8 mm are effective for the 3D analysis of skin microrelief. In addition, accelerated KAZE exhibited the best performance for features extraction and stereo matching. Finally, the extracted 3D information was converted to the actual depth, and the performance of the 3D analysis was verified. Conclusion The proposed system and method that provide texture information are effective for 3D skin disease analysis and evaluation. | - |
dc.format.extent | 12 | - |
dc.language | 영어 | - |
dc.language.iso | ENG | - |
dc.publisher | Blackwell Publishing Inc. | - |
dc.title | Robust skin microrelief depth estimation using a mobile stereo system | - |
dc.type | Article | - |
dc.publisher.location | 미국 | - |
dc.identifier.doi | 10.1111/srt.13204 | - |
dc.identifier.scopusid | 2-s2.0-85138709730 | - |
dc.identifier.wosid | 000860457100001 | - |
dc.identifier.bibliographicCitation | Skin Research and Technology, v.28, no.6, pp 815 - 826 | - |
dc.citation.title | Skin Research and Technology | - |
dc.citation.volume | 28 | - |
dc.citation.number | 6 | - |
dc.citation.startPage | 815 | - |
dc.citation.endPage | 826 | - |
dc.type.docType | Article | - |
dc.description.isOpenAccess | N | - |
dc.description.journalRegisteredClass | scie | - |
dc.description.journalRegisteredClass | scopus | - |
dc.relation.journalResearchArea | Dermatology | - |
dc.relation.journalWebOfScienceCategory | Dermatology | - |
dc.subject.keywordAuthor | mobile stereo system | - |
dc.subject.keywordAuthor | optimization | - |
dc.subject.keywordAuthor | skin three-dimensional analysis | - |
dc.subject.keywordAuthor | stereo matching | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
(31538) 22, Soonchunhyang-ro, Asan-si, Chungcheongnam-do, Republic of Korea+82-41-530-1114
COPYRIGHT 2021 by SOONCHUNHYANG UNIVERSITY ALL RIGHTS RESERVED.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.